INSTALLATION | ||
|
|
|
Read this entire installation section before you start installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such as output terminals or inter- nal wiring.
•Insulate yourself from the work and ground.
•Always wear dry insulating gloves.
Only qualified personnel should install, use or service this equipment.
CONNECTOR KIT INSTALLATION TO GUN CABLE
The K574 and K1722 Magnum® 400 dual procedure cables are shipped as generic assemblies and must be assembled with a connector kit.
NOTE: The K574 Magnum® 400 DP gun and cable is not only shipped with a generic wire feeder end, it is also shipped with generic gun control assem- blies. The brass connector can be installed per K466 instructions, but the gun control cable must be tailored, by the user, to the specific machine.
To install on an
To install on a
&E. Connect the cable clamp to the plug and secure the leads.
The K1722 Magnum® 400DP gun and cable is equipped with a control cable that attaches to a Lincoln
K466-1& -8 INSTALLATION (For Lincoln Feeders)
a.Remove brass cable connector and insulation tube (see Figure B.1) from the kit. Slide the insulation tube onto the connector from the threaded end and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.
b.Remove the molded gas plug fitting on the side of the feeder end handle and replace it with the barbed brass fitting provided in the kit. The includ- ed wrench will fit both the gas plug and barbed fit- ting.
c.The gun control cable provided is not used.
d.Place one tubing clamp onto each end of the flexi- ble tubing provided, approximately 2” (51 mm) in from each end. Slide one end of the tubing onto the barbed connector on the feeder end cable handle (step b) and move the clamp down near the end of the tube to ensure a good gas seal.
NOTE: An optional K481 Magnum®
a. Remove brass cable connector (see Figure B.1) from the kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.
b. Check that the molded gas plug fitting is sealing the gas fitting hole in the side of the feeder end handle.
a. Remove brass cable connector (see Figure B.1) from the kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.
b. Check that the molded gas plug fitting is sealing the gas fitting hole in the side of the feeder end handle.
c. The gun control cable provided is not used.
MAGNUM® 400 DUAL PROCEDURE GUNS