INSTALLATION | ||
|
|
|
a. Remove brass cable connector (see Figure B.1) from the kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.
b. Check that the molded gas plug fitting is sealing the gas fitting hole in the side of the feeder end handle.
c. The gun control cable provided is not used.
K466-7, and K466-10 Installation (Hobart Series
2000 Feeders, and Lincoln
a. Remove brass cable connector (see Figure B.1) from the connector kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.
b. Check that the molded gas plug fitting is sealing the gas fitting hole in the side of the feeder end handle.
c. The gun control cable provided is not used.
Figure B.1
MAGNUM® 400 DUAL PROCEDURE GUNS