CONNECTION TO MILLER FEEDERS
Gun and cable assemblies which were assembled with a
a.Check that the gun liner, connector cap liner, drive rolls and guide tubes are appropriate for the elec- trode size being used.
b.Fully push the brass connector end of the gun and cable into the connector receptacle on the outgoing side of the feeder wire drive. Tighten the hand screw to clamp down on the connector.
c.Insert the control cable plug into the mating socket on the wire feeder.
CONNECTION TO HOBART 2000 FEEDERS
Gun and cable assemblies which were assembled with a
a.Check that the adapter and feeder outgoing guide, as well as the drive roll, are appropriate for the electrode size being used.
b.Fully push the brass connector end of the gun cable into the outgoing side of the feeder wire drive. Secure the cable using the hand screw on the wire feeder.
c.Connect the control cable plug into the mating socket on the wire feeder.
CONNECTION TO LINCOLN -10 SERIES FEEDERS
Gun cable assemblies which were assembled with a
a.Check that the
b.Fully push the brass connector end of the gun cable into the gun adapter on the outgoing side of the feeder wire drive and secure the cable using the hand screw.
c.Insert the control cable plug into the mating socket on the wire feeder.
MAGNUM® 400 DUAL PROCEDURE GUNS