D-2 MAINTENANCED-2
(4 CONTROL LEADS)
CABLE
CONTROL LEAD
Figure E.1
d)Remove gun tube connector from cable by unscrewing connector nut from gun tube connec- tor. If the cable inner tube is difficult to remove from the connector assembly, carefully slit it length- wise with a knife up to the brass connector.
e)Uncouple the strain relief by pushing its outer housing toward the middle of the cable. Move the strain relief and the cable boot toward the middle of the cable, past the damaged section.
f)For K574 models
Cut off damaged section of cable and strip off the outer jacket 2.15 inches back. Be careful not to cut the insulation on the control wires while stripping jacket. Pull control leads back and trim the exposed copper and inner tube back .50 inch. Strip all four control leads .125 inch back and crimp a new
For K1722 models:
Cut off damaged section of cable and strip off the outer jacket 1.65 inches back. Be careful not to cut the insulation on the control wires while stripping jack- et. Strip all four control leads .25 inch back and crimp a new
1/4" (6.4mm) SKIN (4 CONTROL LEADS)
CABLE
CONTROL LEADS
(41.9mm SKIN)
Figure E.2
MAGNUM® 400 DUAL PROCEDURE GUNS