Lincoln Electric 250 manual Troubleshooting

Page 33

E-5

TROUBLESHOOTING

E-5

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The welding arc is “cold.” The welding arc is not stable or is not satisfactory. the engine runs nor- mally. The auxiliary power is nor- mal.

1.Make sure the MODE selector switch is in the correct position for the process being used. (For example, CV-WIRE, PIPE, CC- STICK.)

2.Make sure the electrode (wire, gas, voltage, current etc.) is cor- rect for the process being used.

3.Check for loose or faulty con- nections at the weld output ter- minals and welding cable con- nections.

4.The welding cables may be too long or coiled, causing an exces- sive voltage drop.

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln

Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

RANGER 250

Image 33
Contents Ranger California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Table of Contents Installation Machine Specifications Ranger 250 K1725-2, K1725-4 Safety Precautions PRE-OPERATION Engine Service Electrical Connections Standby Power Connections Auxiliary Power ReceptaclesConnection of Ranger 250 to Premises Wiring Connection of an LN-23P Wire Feeder to the Ranger Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-7 or LN-8 to the Ranger Connection of the LN-25 to the RangerOperation Design FeaturesGeneral Description Engine OperationWelding Controls Weld Mode Selector SwitchARC Control Weld Output Terminals with Flange NUTWire Feeder Voltmeter Switch Weld Terminals Control SwitchEngine Controls PIN AmphenolWelder Operation StoppingTypical Ranger 250 Fuel Consumption Wire WELDING-CV TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingRanger 250 Extension Cord Length Recommendations Accessories T12153-9 50 AMP, 120/240V Power PlugRecommended Optional Equipment Engine Maintenance Components MaintenanceKohler Engine Onan P220 OHVAIR PRE-CLEANER Service AIR Cleaner ServiceEngine OIL Change Engine OIL Refill CapacitiesSpark Plug Service AIR Filter Paper ElementSpark Plug Battery Maintenance Engine Adjustment Overspeed is HazardousCleaning the Battery Charging the BatteryWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingService Facility Persists,Contact your localLincoln Authorized Field Contact your local Lincoln Possible AreasTroubleshooting Troubleshooting Diagrams Diagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams W11 G4284Dimension Print Ranger 22.25 23.5015.25 15.50 Ranger Ranger Precaucion Warnung