Lincoln Electric 250 manual Welding Controls, Weld Mode Selector Switch, ARC Control

Page 18

B-2

OPERATION

B-2

 

 

 

1

2

3

4

WELDING CONTROLS:

1. OUTPUT CONTROL: The CONTROL dial provides continuous control of the welding current or welding voltage depending on the selected welding mode. This control is not active in the CC-STICK, PIPE, and CV-WIRE modes when a remote control or wire feeder with remote control is connected to either the 6 pin or 14 pin Amphenol.

2. WELD MODE SELECTOR SWITCH:

(Provides four selectable welding modes)

CV-WIRE PIPE CC-STICK TOUCH START TIG

15 14

13

12

11

10

9

8

7

6

5

CC-STICK/PIPE modes: In these modes, the ARC CONTROL knob sets the short circuit current during stick welding (arc-force). Increasing the number from - 10 to +10 increases the short circuit current and pre- vents sticking of the electrode to the plate while weld- ing. This can also increase spatter. It is recommended that the ARC CONTROL be set to the minimum num- ber without electrode sticking. Start with a setting at 0.

CV-WIRE mode: In this mode, turning the ARC CON- TROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance control. The proper setting depends on the procedure and operator preference. Start with a setting at 0.

3. ARC CONTROL :

The ARC CONTROL WIRE/STICK dial is active in the WIRE, STICK and PIPE modes, and has different functions in these modes. This control is not active in the TIG mode. DC PIPE mode for machines below code 10900.

4.WELD OUTPUT TERMINALS WITH FLANGE NUT:

Provides a connection point for the electrode and work cables.

RANGER 250

Image 18
Contents Ranger Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Table of Contents Installation Machine Specifications Ranger 250 K1725-2, K1725-4 Safety Precautions PRE-OPERATION Engine Service Electrical Connections Auxiliary Power Receptacles Standby Power ConnectionsConnection of Ranger 250 to Premises Wiring Connection of LN-7 or LN-8 to the Ranger Connection of Lincoln ELEC- Tric Wire FeedersConnection of an LN-23P Wire Feeder to the Ranger Connection of the LN-25 to the RangerGeneral Description Design FeaturesOperation Engine OperationARC Control Weld Mode Selector SwitchWelding Controls Weld Output Terminals with Flange NUTEngine Controls Weld Terminals Control SwitchWire Feeder Voltmeter Switch PIN AmphenolWelder Operation StoppingTypical Ranger 250 Fuel Consumption Wire WELDING-CV TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingRanger 250 Extension Cord Length Recommendations Accessories T12153-9 50 AMP, 120/240V Power PlugRecommended Optional Equipment Kohler Engine MaintenanceEngine Maintenance Components Onan P220 OHVEngine OIL Change AIR Cleaner ServiceAIR PRE-CLEANER Service Engine OIL Refill CapacitiesSpark Plug Service AIR Filter Paper ElementSpark Plug Cleaning the Battery Engine Adjustment Overspeed is HazardousBattery Maintenance Charging the BatteryWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideService Facility Persists,Contact your localLincoln Authorized Field Possible Areas Contact your local LincolnTroubleshooting Troubleshooting Diagrams Diagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams G4284 W11Dimension Print Ranger 22.25 23.5015.25 15.50 Ranger Ranger Precaucion Warnung
Related manuals
Manual 2 pages 32.25 Kb Manual 27 pages 21.85 Kb