| INSTALLATION |
|
|
|
|
|
| ||||||
| TECHNICAL SPECIFICATIONS - PRECISION TIG 225 | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INPUT - SINGLE PHASE ONLY |
|
|
|
|
| ||||||||
|
| Standard Voltage | Input Current at Rated Output | Power Factor |
| Idle Current |
| |||||||||
| 208/230/1/60 |
|
|
| 42A / 39A Effective |
| 0.62 Min. |
| 3.0A/2.7A Max. |
| ||||||
|
|
| and 94A / 85A Maximum |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT RANGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Maximum Open |
|
|
|
|
|
|
|
|
| |||
|
| Output Current |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Type of Output | |||||||||||
|
| Range |
|
|
| Circuit Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (STICK AND TIG) |
|
|
|
| CC (Constant Current) |
|
| |||
|
|
|
|
| AC OCV: 75 |
|
|
|
|
| AC/DC |
|
| |||
|
|
|
|
| DC OCV: 66 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OUTPUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Weld Current* |
|
|
|
| Weld Voltage (NEMA) | ||||||||||
|
| Process Duty Cycle** |
|
|
|
|
|
|
|
|
| |||||
|
| GTAW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10% Duty Cycle |
|
|
| 225A AC/DC |
|
|
|
| 15.7 V AC/DC |
|
| |||
|
| 20% Duty Cycle |
|
|
| 180A AC/DC |
|
|
|
| 15.2 V AC/DC |
|
| |||
|
| 100% Duty Cycle |
|
|
| 90A AC/DC (BAL.) |
|
|
|
| 14.1 V AC/DC |
|
| |||
|
|
|
|
|
| 80A AC |
|
|
|
| 14.0 V AC/DC |
|
| |||
|
| SMAW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10% Duty Cycle |
|
|
| 225A AC/DC |
|
|
|
| 29.0 V AC/DC |
|
| |||
|
| 20% Duty Cycle |
|
|
| 180A AC/DC |
|
|
|
| 27.2 V AC/DC |
|
| |||
|
| 100% Duty Cycle |
|
|
| 90A AC/DC |
|
|
|
| 23.4 V AC/DC |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
**Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle). (Example; 180A@20% for AC/DC Stick and TIG)
* Inputs and
$$
+ |
|
| . | / |
* |
| 01 | ||
) |
| 3/0 | 3/ | |
' |
| 23/3/ |
| |
( |
| 23//01 | ||
# |
|
|
| |
%&)%+% |
|
|
| |
|
|
|
|
1Output Limits allow for continuous max. rated load on 115vac auxiliary receptacle.
2Wiring and protection based on the 2005 U.S. National Electric Code.
Use a Super Lag type fuse or circuit breaker with a delay in tripping action.
Models with NEMA