Lincoln Electric 400 (AU) manual Installation, Technical Specifications Vantage 400 AU K32038-1

Page 11

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - VANTAGE® 400 (AU) (K32038-1)

Make/Model Code No.

Perkins 404D-22

 

 

INPUT - DIESEL ENGINE

 

 

Description

Speed (RPM)

Displacement

Starting

 

 

 

cu. in. (ltrs.)

System

4 cylinder

 

135.6(2.2)

12VDC Battery

27.6

HP

High Idle 1565

 

& starter

 

1500

RPM

 

Bore x Stroke

(Group 34; 650

naturally aspirated

Full Load 1500

cold crank amps)

 

water cooled

 

3.43” X 3.64”

65 Amp Alternator

Diesel Engine

Low Idle 1200

(87.1mm x 92.5mm)

W / Built in Regulator

 

 

 

 

 

 

 

 

 

 

Capacities

Oil:

8.45Qts. (8.0L) Fuel: 20 gal. (75.7 L)

Radiator Coolant: 8.0Qts. (7.6L)

RATED OUTPUT @ 104° F (40° C) - WELDER

Welding Process

Welding Output

Output Range

Max. Weld OCV

 

Current/Voltage/Duty Cycle

 

@Rated Load RPM

DC Constant Current

350A / 34V / 100%

30 TO 400 AMPS

 

DC Pipe Current

300A / 32V / 100%

40 TO 300 AMPS

60 Volts (2)

Touch-Start™TIG

250A / 20V / 100%

20 TO 250 AMPS

 

DC Constant Voltage

350A / 34V / 100%

14 TO 34 VOLTS

 

Arc Gouging

350A / 34V / 100%

90 TO 400 AMPS

60 Volts

RATED OUTPUT @ 40° C (104° F).- GENERATOR

Auxiliary Power (1)

14,000 Watts Peak / 13,200 Watts Continuous, 50 Hz 400 Volts 3-Phase 6,900 Watts Peak(3) / 6,900 Watts Continuous, 50 Hz 230 Volts 1-Phase Sound Levels (Sound power: 96 dB Lwa)

ENGINE

LUBRICATION

 

EMISSIONS

 

 

FUEL SYSTEM

 

 

GOVERNOR

Full Pressure

 

 

 

Mechanical Fuel Pump, Auto air bleed

 

 

Mechanical

with Full Flow Filter

EPA Tier IV Interim

 

system, Electric shutoff solenoid, Indirect fuel injector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR CLEANER

ENGINE IDLER

 

 

MUFFLER

 

ENGINE PROTECTION

 

 

 

 

Low noise Muffler:

 

 

Shutdown on low oil

Single Element

 

Automatic Idler

 

Top outlet can be rotated.

 

 

pressure & high engine

 

 

 

Made from long life, aluminized steel.

 

 

coolant temperature

ENGINE WARRANTY:

2 years / 2000 hours, all non-electric components, 3 years major non-electric compo-

nents . See Perkins warranty for details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

HEIGHT

 

WIDTH

 

 

DEPTH

 

 

WEIGHT

35.94 (4) in.

 

27.00 in

 

 

60.00 in.

 

 

 

 

 

 

 

 

 

 

 

1230 lbs. (559kg.)

 

913 mm

 

686 mm

 

 

1524 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

(2)Reduced to less than 30V in the CC-stick Mode when VRD (VOLTAGE REDUCTION DEVICE) is on.

(3)Maximum per circuit breaker rating.

(4)To Top of enclosure. Add 7.35 (186.7mm) to top of exhaust. Add 3.87”(98.3mm) to top of Lift Bail.

VANTAGE® 400 (AU)

Image 11
Contents Vantage California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents 641 Section DSection E Section FTechnical Specifications Vantage 400 AU K32038-1 InstallationMachine Specifications Location and Ventilation Safety PrecautionsVRD Voltage Reduction Device Vehicle Mounting PRE-OPERATION Engine ServiceHigh Temperature Operation TowingFuel Battery ConnectionRemote Control OILElectrical Connections Control Cable Model Auxiliary PowerAcross The-Arc Model 8INSTALLATIONA-8 General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchStarting the Engine Engine ControlsGlow Plug Push Button Circuit BreakerDuty Cycle Stopping the EngineWelder Operation Constant Current CC-STICK WeldingTable B.3 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 MAX Table B.6 Wire WELDING-CVARC Gouging Table B.4TIG Options AccessoriesField Installed Options / Accessories Wire Feeder OptionsRoutine Maintenance MaintenanceOIL Filter Change AIR CleanerEngine OIL Change Service Instructions Bleeding the Fuel System Cooling SystemTightening the FAN Belt Arrestor Engine AdjustmentBattery Maintenance Servicing Optional SparkWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityWelding without a control cable Solenoid Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams Wiring Diagram Vantage 400 AU Dimension PrintVantage 400 AU Vantage 400 AU Precaucion Warnung