Lincoln Electric 400 (AU) manual Cooling System, Tightening the FAN Belt, Bleeding the Fuel System

Page 30

D-4

MAINTENANCE

D-4

 

 

 

COOLING SYSTEM

WARNING

HOT COOLANT can burn skin.

• Do not remove cap if radiator is hot.

------------------------------------------------------------------------

Check the coolant level by observing the level in the radiator and recovery bottle. Add 50/50 antifreeze / water solution if the level is close to or below the "LOW" mark. do not fill above the "FULL" mark. Remove radiator cap and add coolant to radiator. Fill up to the top of the tube in the radiator filler neck which includes a connecting hose coming from the thermostat housing.

To drain the coolant, open the valve at the bottom of the radiator. Open the radiator cap to allow complete drainage. (Tighten the valve and refill with a 50/50 antifreeze/water solution.) Use an automotive grade (low silicate) ethylene glycol antifreeze. The cooling system capacity is 8.0 quarts (7.6L.). Squeeze upper and lower radiator hoses while filling to bleed air from system coolant. Replace and tighten the radiator cap.

CAUTION

Always premix the antifreeze and clean tap water before adding to the radiator. It is very important that a precise 50/50 solution be used with this engine year round. This gives proper cooling dur- ing hot weather and freezing protection to -34° F (- 37° C).

Cooling solution exceeding 50% ethylene glycol can result in engine overheating and damage to the engine. Coolant solution must be premixed before adding to radiator.

------------------------------------------------------------------------

Periodically remove the dirt from the radiator fins. Periodically check the fan belt and radiator hoses. Replace if signs of deterioration are found.

TIGHTENING THE FAN BELT

If the fan belt is loose, the engine can overheat and the battery lose its charge. Check tightness by press- ing on the belt midway between the pulleys. It should deflect about .25 in.(6.4 mm) under a load of 20 lbs.(9 Kg).

FUEL

DIESEL FUEL ONLY-Low sulphur fuel or ultra low sulphur fuel in U.S.A. and Canada.

At the end of each day’s use, refill the fuel tank to min- imize moisture condensation and dirt contamination in the fuel line. Do not overfill; leave room for the fuel to expand.

Use only fresh No. 2D diesel fuel, the use of No. 1D diesel fuel is recommended in place of No. 2D at tem- peratures below 23°F (-5°C). Do not use kerosene.

See the Engine Operator's Manual for instructions on replacing the fuel filter.

BLEEDING THE FUEL SYSTEM

You may need to bleed air from the fuel system if the fuel filter or fuel lines have been detached, the fuel tank has been ran empty or after periods of long stor- age. It is recommended that the fuel shutoff valve be closed during periods of non-use.

WARNING

To avoid personal injury, do not bleed a hot engine. This could cause fuel to spill onto a hot exhaust manifold, creating a danger of fire.

------------------------------------------------------------------------

Bleed the fuel system as follows:

1.Fill the fuel tank with fuel.

2.Open the fuel shut off valve.

3.Loosen bleed fitting on the fuel injector manifold.

4.Operate hand priming lever until fuel comes out the bleed screw on the injector manifold. This could take 20-30 seconds of rapid operation of the prim- ing lever. Tighten bleed fitting on injector manifold.

5.Follow normal STARTING procedures until engine starts.

VANTAGE® 400 (AU)

Image 30
Contents Vantage Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Safety Thank You Table of Contents Section F Section DSection E 641Installation Technical Specifications Vantage 400 AU K32038-1Machine Specifications Safety Precautions VRD Voltage Reduction DeviceLocation and Ventilation Towing PRE-OPERATION Engine ServiceHigh Temperature Operation Vehicle MountingOIL Battery ConnectionRemote Control FuelElectrical Connections Auxiliary Power Across The-Arc ModelControl Cable Model 8INSTALLATIONA-8 Operation General DescriptionWeld Mode Selector Switch Figure B.1Wire Feeder Voltmeter Switch Table B.1Circuit Breaker Engine ControlsGlow Plug Push Button Starting the EngineConstant Current CC-STICK Welding Stopping the EngineWelder Operation Duty CycleTIG Welding Typical Current Ranges 1 for Tungsten ELECTRODES2Table B.3 Table B.4 Wire WELDING-CVARC Gouging MAX Table B.6Wire Feeder Options AccessoriesField Installed Options / Accessories TIG OptionsMaintenance Routine MaintenanceAIR Cleaner Engine OIL ChangeOIL Filter Change Service Instructions Cooling System Tightening the FAN BeltBleeding the Fuel System Servicing Optional Spark Engine AdjustmentBattery Maintenance ArrestorWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnWelding without a control cable Solenoid Faulty control cable. Repair or Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Diagrams Diagrams Wiring Diagram Dimension Print Vantage 400 AUVantage 400 AU Vantage 400 AU Precaucion Warnung