How to Install the Unit

1.To prevent vibration and excess noise, make sure the unit is installed securely and firmly.

2.If possible Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet, as it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Cooled air

30"~60"

Fence

Awning

Heat radiation

About 1/2"

Over 20"

ENGLISH

CAUTION: DO NOT cover or block any of the side louvers. All side louvers of the cabinet must remain exposed and unobstructed to the outside of the structure.

4.Install the unit with a rear, downward slope, so the back is slightly lower than the front (about 1/4" bubble on a level). This will force condensation to flow to the outside.

5.Install the unit with the bottom about 30"- 60" above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to sturdy wood, masonry, or metal.

This unit is designed for installation in standard double hung windows with actual opening widths from 22" to 36".

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 15" from the bottom of the upper sash to the window stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22" to 36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15" min

Stool

 

 

 

 

 

 

(With frame curtain)

 

 

 

 

 

Offset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2" to 11/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sill

 

 

 

 

 

Interior wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exterior

 

 

 

 

 

20 1/12" min.

 

 

 

 

 

 

 

 

 

 

(Without frame curtain)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Image 11
Contents CP06 CP08 Table of Contents For the Best Cooling Performance and Energy Efficiency IntroductionBefore Operating Your Unit English Safety PrecautionsPage This button can automatically control the air flow direction Vent Control Adjusting the Air Flow DirectionAdjusting the Air Flow Direction Drainage Care and MaintenanceAir Filter Hardware Location Product FeaturesInstallation Instructions Window Requirements How to Install the UnitInstallation Kit Contents English Open the window. Mark a line on center Cabinet InstallationPower cord ScrewType a With a Type C Through-the-Wall Installation Instructions-Optional Normal Operation Troubleshooting TipsRoom AIR Conditioners Limited Warranty De votre climatiseur de pièce Table des matières Nutilisez Jamais un fil de rallonge Avant dutiliser votre appareilAvertissement Mesures de SécuritéBords POINTUS! Les bords du cas peuvent être pointus Oscillation Automatique Fonctionnement de la télécommande CPRéglage de l’orientation du débit d’air Commande de l’orifice de ventilationRéglage de lorientation du débit dair Filtre à air Soins et entretienCaractéristiques particulières de l’appareil Installation du matérielPage Dimensions de fenêtre minimales Installation de l’appareilContenu du nécessaire d’installation Préparation DU Cadre Outils recommandésAngle avant Installation du boîtierCordon Dalimentation Vis Type a 1 Vis Type a Étrier de verrouillage de fenêtre Installation sur le mur Instruction facultative Page Garantie limitée Climatiseurs Friedrich CP Lines Contenidos Provee buen flujo de aire IntroducciónAdvertencia Precaucion Precauciones de segoridadPrecaucion Funcionamiento del control remoto CP Ajustar la dirección del flujo de aire Ajustar la dirección del flujo de aireControl de ventilación Drenaje Cuidado y mantenimientoFiltro de Aire a Funciones del producto Instalación de la unidadPage Requisitos de la ventana Cómo instalar la unidadContenidos de los conjuntos de instalación Preparación DEL Chasis Requisitos sugeridos de las ventanasAsiento de la ventana Angulo frontal Instalación del gabineteTornillo Tipo a Abrazadera de fijación Page Instrucciones de instalacion a traves de la pared opcional Page Garantia Limitada -PRIMER AÑO Friedrich AIR Conditioning CO

CP06/CP08 specifications

The Friedrich CP06 and CP08 models are pioneering climate control solutions designed to enhance indoor air quality and comfort. Combining state-of-the-art technology with user-friendly designs, these portable air conditioning units are ideal for both residential and commercial settings.

One of the standout features of the Friedrich CP units is their impressive cooling capacity. The CP06 model offers a cooling output of approximately 6,000 BTUs, effectively cooling spaces up to 250 square feet, while the CP08 steps it up to 8,000 BTUs, catering to rooms of up to 350 square feet. This versatility makes them suitable for various applications, from small bedrooms to larger living areas.

Energy efficiency is another hallmark of the Friedrich CP series. Both models are designed with a high Energy Efficiency Ratio (EER), minimizing electricity consumption while maximizing performance. This energy-saving capability is crucial for environmentally-conscious users looking to reduce their carbon footprint and lower energy bills.

Furthermore, the Friedrich CP06 and CP08 come equipped with advanced technologies that enhance user experience and comfort. For instance, the models feature a programmable timer and a remote control, allowing users to adjust settings from a distance. This convenience ensures that spaces are cooled to the desired temperature before arrival, combining comfort with efficiency.

In terms of design, the units boast a sleek and modern appearance that complements various interior styles. They are designed to be portable, with integrated handles and caster wheels, making it easy to move them from one room to another. Additionally, both models operate quietly, ensuring minimal disruption in home or office environments.

The Friedrich CP series emphasizes air quality, incorporating a washable, reusable filter that captures dust, pollen, and other airborne particles. This feature not only maintains cleaner air but also prolongs the lifespan of the unit.

In summary, the Friedrich CP06 and CP08 portable air conditioners deliver exceptional cooling performance, energy efficiency, and user-friendly features. With their advanced technology, silent operation, and emphasis on air quality, these models stand out as reliable solutions for maintaining comfort in any indoor setting. Whether for a home or business, the Friedrich CP series is an investment in both comfort and sustainability.