OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Pressure

Switch"On/Auto/

Off" Switch

Safety Valve

Outlet

Pressure GaugeTank

Pressure Gauge

Regulator

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch "ON/AUTO" to provide automatic power to the pressure switch and "OFF" to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet

pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank

pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Drain Valve:

 

 

 

 

 

 

The drain valve

 

 

 

is located at

 

 

 

the base of the

 

 

 

 

Drain

air tank and is

 

Valve

 

used to drain

 

 

 

 

 

 

condensation

 

 

 

 

 

 

at the end of each use.

 

 

13- ENG

A14841

Image 13
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Location away from compressor Operate compressor in a clean, dry wellRestrict the flow of fresh air to Ventilation openingsWhat Could Happen Attachments & AccessoriesElectricity. Like any other electrically Safety equipment must be properlyRepairs attempted by unqualified Personnel can result in serious injuryResult in serious burns Or attempt maintenance until unit hasHot for several minutes after operation Do not reach around protective shroudsWhen Transporting Compressor Accessories AccessoriesGlossary Duty Cycle Assembly Location of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Voltage and Circuit Protection Extension CordsDescription of Operation OperationOutlet Pressure Gauge The outlet Tank Pressure Gauge The tankPressure Release Valve Break-in ProcedureBefore Each Start-Up To Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection and ReplacementMotor Air FilterTo Replace or Clean Check Valve Service and AdjustmentsRing Nut Outlet Tube Pressure Relief Check ValveRegulator Tank OutletPressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Being used Check wiring connection Pleine Garantie D’UN AN Table DES MatièresMesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Avertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Avertissement Risque dune utilisation dangereuse RisqueCycle DE Service AccessoiresAccessoires LexiqueAssemblage Montage DE Lappareil Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Avant le démarrage Utilisation de lappareilArrêt de lappareil Procédures de rodageMise en marche Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirMoteur Filtre à air Inspection et remplacementEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenueLentretien Purgez lair pressurisé du réservoirRemplacement du régulateur Rangement Serrer DépannagePas Percer, souder ni modifierEst utilisé, ajustez le régulateur Pas Surcharges déclenché 54- FR 55- FR A14841 Get it fixed, at your home or ours