Craftsman 919.724591 Maintenance, Customer Responsibilities, To Check Safety Valve, To Drain Tank

Page 16

MAINTENANCE

Customer Responsibilities

 

Before

Daily

Every

Every

 

 

or after

 

 

each

each

40

100

Yearly

 

use

use

hours

hours

 

 

 

 

Check Safety Valve

 

 

 

 

Drain Tank

 

 

 

 

Air Filter

 

 

●(1)

 

Air compressor pump intake

 

 

 

 

and exhaust valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1- more frequent in dusty or humid conditions

 

 

 

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

To ensure efficient operation and longer life of the air compressor unit, a routine maintenance schedule should be prepared and followed. The above routine maintenance schedule is geared to an unit in

a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor units in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve

is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the "On/Auto/Off" lever to "OFF".

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter- clockwise) on bottom of tank.

A14841

16- ENG

Image 16
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Operate compressor in a clean, dry well Location away from compressorRestrict the flow of fresh air to Ventilation openingsAttachments & Accessories What Could HappenSafety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Personnel can result in serious injuryOr attempt maintenance until unit has Result in serious burnsHot for several minutes after operation Do not reach around protective shroudsWhen Transporting Compressor Accessories AccessoriesGlossary Duty CycleAssembly Location of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Extension Cords Voltage and Circuit Protection Operation Description of Operation Outlet Pressure Gauge The outlet Tank Pressure Gauge The tankBreak-in Procedure Pressure Release ValveBefore Each Start-Up Maintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesMotor Air FilterService and Adjustments To Replace or Clean Check ValveRing Nut Outlet Tube Pressure Relief Check ValveRegulator Tank OutletPressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Being used Check wiring connection Table DES Matières Pleine Garantie D’UN ANMesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires Cycle DE ServiceAccessoires LexiqueAssemblage Emplacement du compresseur dair Montage DE LappareilRallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Utilisation de lappareil Avant le démarrageArrêt de lappareil Procédures de rodageAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirFiltre à air Inspection et remplacement MoteurRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesLentretien Purgez lair pressurisé du réservoirRemplacement du régulateur Rangement Dépannage SerrerPas Percer, souder ni modifierEst utilisé, ajustez le régulateur Pas Surcharges déclenché 54- FR 55- FR A14841 Get it fixed, at your home or ours