Compresor lubricado con aceite | HL5402 |
HL5402
Garantía Limitada
1. DURACIÓN: A partir de la fecha de compra por el comprador original: Un Año. | |
2. QUIEN OTORGA ESTA GARANTÍA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio | |
45030 Teléfono: (800) | |
3. QUIEN RECIBE ESTA GARANTÍA (EL COMPRADOR): El comprador original (que no sea un revendedor) del producto Campbell Hausfeld. | |
4. PRODUCTOS CUBIERTOS POR ESTA GARANTÍA: Cualquier compresor de aire Campbell Hausfeld. | |
5. COBERTURA DE LA GARANTÍA: Piezas y Mano de Obra para remediar defectos importantes debidos a material y mano de obra durante | |
el primer año de propiedad con las excepciones indicadas a continuación. | |
6. LO QUE NO ESTÁ CUBIERTO POR ESTA GARANTÍA: | |
A. Las garantías implícitas, incluyendo aquéllas de comerciabilidad e IDONEIDAD PARA FINES PARTICULARES, ESTÁN LIMITADAS A | |
PARTIR DE LA FECHA DE COMPRA ORIGINAL DE ACUERDO CON LO ESPECIFICADO EN EL PÁRRAFO DE DURACIÓN. Si el compresor de | |
aire es empleado para uso comercial, industrial o para renta, la garantía será aplicable por noventa (90) días a partir de la fecha de | |
compra. En algunos estados no se permiten las limitaciones a la duración de una garantía implícita, por lo cual las limitaciones | |
antedichas pueden no ser aplicables en su caso. | |
B. CUALQUIER PÉRDIDA DAÑO INCIDENTAL, INDIRECTO O CONSECUENTE QUE PUEDA RESULTAR DE UN DEFECTO, FALLA O | |
MALFUNCIONAMIENTO DEL PRODUCTO CAMPBELL HAUSFELD. En algunos estados no se permite la exclusión o limitación de daños | |
incidentales o consecuentes, por lo tanto, en tales casos esta limitación o exclusión no es aplicable | |
C. Cualquier falla que resulte de un accidente, abuso, negligencia o incumplimiento de las instrucciones de funcionamiento y uso | |
indicadas en el (los) manual(es) que se adjunta(n) al compresor. | |
D. Los servicios requeridos antes de la entrega tales como: ensamblaje, aceite o lubricantes y ajustes. | |
E. Artículos o servicios normalmente requeridos para el mantenimiento del producto, tales como:lubricantes, filtros, empaques, etc. | |
F. Los motores de gasolina están específicamante excluidos de la cobertura de esta garantía limitada. El comprador debe seguir las | |
clausulas de la garantía otorgada por el fabricante del motor de gasolina que se suministra con el producto. | |
G. Artículos adicionales no cubiertos bajo esta garantía: | |
1. Piezas excluidas que pertenecen a Todos los Compresores | |
a. Cualquier componente dañado durante el envío o cualquier daño ocasionado por haber instalado u operado la unidad bajo | |
| condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o daños ocasionados por el contacto |
| con herramientas o los alrrededores. |
b. Daños del cabezal o las válvulas ocasionados por la lluvia, humedad excesiva, agentes corrosivos u otros contaminantes. | |
c. | Daños de apariencia que no afecten el funcionamiento del compresor. |
d. Tanques oxidados, incluyendo pero no limitado al óxido debido al drenaje inadecuado u agentes corrosivos en el ambiente. | |
e. Las siguientes piezas se consideran artículos sujetos a desgaste normal y no son cubiertas después del primer año de | |
| propiedad. |
| Motor eléctrico, válvula de retención, interruptor de presión, regulador, manómetros, mangueras, tuberías, tubos, accesorios |
| y acoples, tornillos, tuercas, artículos de ferretería, correas, poleas, volante, filtro de aire y caja, juntas, sellos, pérdidas de |
| aceite, pérdidas de aire, consumo o uso de aceite, anillos del pistón. |
f. | Llaves de drenaje |
g. Daños debidos al alambrado incorrecto o conexión a cicuitos con voltaje inadecuados para la unidad. | |
h. Otros artículos no enumerados pero considerados de desgaste general. | |
i. Presostatos, controles de flujo de aire y válvulas de seguridad cuyos parametros fijados de fábrica se modifiquen. | |
j. Daño por mantenimiento inadecuado del filtro. | |
k. Motores de inducción alimentados con electricidad producida por un generador. |
Grounding
Pin
TEST RESET
Grounded Outlet
Figure 1 - Grounding Method
LUBRICATION
THIS UNIT
IS SHIPPED
WITHOUT OIL! Follow lubrication instructions before operating compressor.
Use oil shipped with the compressor.
Do not use regular automotive oil
such as
The compressor pump takes approximately 175mL (6 oz) of oil. The sight glass, located on the crankcase portion of the pump, is used to determine proper oil level. Fill the crankcase with oil until the level is in the middle of the sight glass. Avoid overfilling by adding oil gradually and checking the oil level with
the sight glass several times. Add enough oil to reach the “max” level on the sight glass. Proper oil level is illustrated in Figure 3.
Max. |
Min. |
Figure 3 - Proper oil level |
Operation
•Pressure Switch - Auto/Off Switch - In the AUTO position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure. In the OFF position, the compressor will not operate. This switch should be in the OFF position when connecting or disconnecting the power cord from the electrical outlet or when changing air tools.
•Regulator - The regulator controls the amount of air pressure released at the hose outlet.
•ASME Safety Valve - This valve is located on the bottom of the pressure switch. It will automatically releases air if the tank pressure exceeds the preset maximum.
•Exhaust Tube - This tube carries compressed air from the pump to the check valve. This tube becomes very hot during use. To avoid the risk of severe burns, never touch the discharge tube.
•Check Valve - This valve is located at the end of the exhuast tube where it meets the tank. It is a one- way valve that allows air to enter the tank, but prevents air in the tank from flowing back into the compressor pump.
•Handle - Designed to move the compressor.
Never use the
handle on wheeled units to lift the unit completely off the ground.
•Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture from tank by opening the drain valve
2. Compresores lubricados |
a. Daños del cabezal o las válvulas debidos al uso de aceites no especificados. |
b. Daños del cabezal o las válvulas debidos a cualquier contaminación del aceite o por no haber seguido las instrucciones de |
lubricación. |
c. Desgaste o daño de la bomba causados por el no haber aplicado apropiadamente los criterios de mantenimiento en referencia |
al aceite, funcionamiento con nivel de aceite por debajo del nivel apropiado o funcionamiento sin aceite. |
7. RESPONSABILIDADES DEL GARANTE BAJO ESTA GARANTÍA: Reparar o reemplazar, como lo decida el Garante, el compresor o |
componentes que estén defectuosos, se hayan dañado o hayan dejado de funcionar adecuadamente, durante el período de validez de |
la garantía |
8. RESPONSABILIDADES DEL COMPRADOR BAJO ESTA GARANTÍA: |
A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto. |
B. Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más |
cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador. |
C. Tener cuidado al utilizar el producto, tal como se indica(n) en el (los) manual(es) del propietario. |
D. Reparaciones que requieran tiempo adicional al horario normal de trabajo, o cualquier asunto que exceda la tarifa normal de |
reembolso por mano de obra para reparaciones bajo la garantía del fabricante. |
E. El tiempo requerido por cualquier control de seguridad, capacitación relacionada con seguridad, o asuntos similares necesarios para |
que el personal de servicio pueda tener acceso a las instalaciones. |
F. La ubicación de la unidad debe tener espacio suficiente para que el personal de servicio pueda realizar reparaciones y debe ser |
fácilmente accesible. |
9. CUÁNDO EFECTUARÁ EL GARANTE LA REPARACIÓN O REEMPLAZO CUBIERTO BAJO ESTA GARANTÍA: La reparación o reemplazo |
dependerá del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos. |
Esta garantía limitada es válida sólo en los EE.UU., Canadá y México y otorga derechos legales específicos. Usted también puede tener otros derechos que varían de un Estado a otro. o de un país a otro.
Handle |
Pressure Switch |
Regulator |
Exhaust Tube |
Figure 2 - Unit Identification |
located underneath the tank.
BEFORE FIRST START-UP
BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.)
1.Turn regulator knob fully clockwise (to the right) to open air flow.
2.Turn on/off switch to OFF position.
3.Plug in power cord.
4.Turn on/off switch to ON position and run compressor for 30 minutes.
5.Turn on/off switch to OFF position.
30
|
|
| Extension cords for 120V/15 Amp Unit |
|
|
|
| ||
Length of Cord (ft) | 25 | 50 | 100 | 150 | 200 | 250 | 300 | 400 | 500 |
Gauge of Cord | 16 | 12 | 10 | 8 | 6 | 6 | 4 | 4 | 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
30