Oil Lubricated Compressors
Troubleshooting Chart
Symptom | Possible Cause(s) | Corrective Action | ||
Compressor will not run | 1. | Switch in OFF position | 1. | Make sure compressor is plugged in and switch is ON. |
| 2. | No electrical power at wall outlet | 2. | Check circuit breaker or fuse at electrical panel. |
| 3. | Compressor has reached automatic | 3. | Release air from tank until compressor restarts |
|
| shutoff pressure |
| automatically. |
| 4. | Motor overheated | 4. | Allow compressor to cool for approximately 30 |
|
|
|
| minutes so thermal overload switch will reset. Make |
HL5402
Para ordenar repuestos, sírvase llamar al distribuidor más cercano a su domicilio
Sírvase darnos la siguiente información: |
|
|
|
| Puede escribirnos a: |
|
| |
|
|
|
| Attn: Parts Dept. |
|
| ||
|
|
|
| 100 Production Drive |
|
| ||
|
|
| Harrison, OH 45030 USA |
|
| |||
|
|
|
|
|
|
|
| |
No. de |
|
|
|
| No. de |
|
| |
Ref. | Descripción | FP2020 | Ctd. |
| Ref. | Descripción | FP2020 | Ctd. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| sure compressor is run in a clean, | |
|
| 5. | Pressure switch bad | 5. | Replace pressure switch. | ||
|
|
|
|
| |||
| Motor hums but cannot | 1. Defective check valve | 1. | Repair or replace. | |||
| run or runs slowly | 2. Defective unloader valve (on pressure | 2. | Repair or replace. | |||
|
|
| switch) |
|
|
|
|
|
| 3. | Low voltage | 3. | Check voltage at wall outlet with voltmeter. | ||
|
| 4. | Loose electrical connections | 4. | Check all electrical connections. | ||
|
| 5. | Wrong gauge wire or length of | 5. | Check extension cord chart for proper extension cord | ||
|
|
| extension cord |
|
| usage. | |
|
| 6. | Defective motor capacitor | 6. | Replace capacitor. | ||
|
| 7. | Shorted or open motor winding | 7. | Replace motor assembly. | ||
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
| bleed tank | |||
|
|
|
|
| |||
| Flow blows/circuit | 1. Incorrect fuse size, circuit overloaded | 1. | Check for proper fuse. Use time delay fuse. | |||
| breaker trips repeatedly |
|
|
|
| Disconnect other electrical appliances from circuit or | |
|
|
|
|
|
| operate compressor on its own branch circuit. | |
|
| 2. | Wrong gauge wire or length of | 2. | Check extension cord chart for proper extension cord | ||
|
|
| extension cord |
|
| usage. | |
|
| 3. | Defective check valve | 3. | Repair or replace. | ||
|
| 4. | Defective unloader valve (on pressure | 4. | Repair or replace. | ||
|
|
| switch) |
|
|
|
|
|
| 5. | Defective motor capacitor | 5. | Replace capacitor. | ||
|
| 6. | Motor shorted or seized | 6. | Replace motor assembly. | ||
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
|
|
|
| |
|
|
|
| bleed tank | |||
|
|
|
|
| |||
| Thermal overload | 1. Low voltage | 1. | Check voltage at wall outlet with voltmeter. | |||
| protector cuts out | 2. Wrong gauge wire or length of | 2. | Check extension cord chart for proper extension cord | |||
| repeatedly |
| extension cord |
|
| usage. | |
|
| 3. | Clogged intake filter | 3. | Clean or replace filter. | ||
|
| 4. | Lack of proper ventilation/room | 4. | Move compressor to | ||
|
|
| temperature too high |
|
|
|
|
|
| 5. | Defective check valve | 5. | Repair or replace. | ||
|
| 6. | Defective unloader valve (on pressure | 6. | Repair or replace. | ||
|
|
| switch) |
|
|
|
|
|
| 7. | Compressor valves failed | 7. | Replace valve assembly. | ||
|
|
|
|
|
|
| Do not disassemble check |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| valve with air in tank; |
|
|
|
|
|
|
| |
|
|
|
| bleed tank | |||
|
|
|
|
|
|
| |
| Knocks, rattles, and/or | 1. Loose mounting bolts | 1. Tighten bolts. | ||||
| excessive vibration | 2. Tank not level | 2. Use sturdy wedge/object to bring tank to level position. | ||||
|
| 3. | Cylinder or piston is worn/scored |
|
|
|
|
|
|
|
|
|
|
|
|
1 | Tapa | ▲ | 1 |
2 | Filtro de aire |
|
|
| (incluye los elementos) | HL030100AV | 1 |
3 | Codo | HL030200AV | 1 |
4 | Arandela | ■, ▲ | 8 |
5 | Perno del cabezal | ■ | 4 |
6 | Cabeça do cilindro | ■ | 1 |
7 | Junta del cabezal | ● | 1 |
8 | Placa de la válvula | ◆ | 2 |
9 | Junta metálica | ◆ | 1 |
10 | Válvula | ◆ | 2 |
11 | Empaque para la placa de |
|
|
| la válvula | ● | 1 |
12 | Cilindro | ★ | 1 |
13 | Perno del cilindro | ▼ | 2 |
14 | Empaque del cilindro | ● | 1 |
15 | Pasador | ★ | 1 |
16 | Anillo de compresión | ★ | 2 |
17 | Anillo de aceite | ★ | 1 |
18 | Retenes del pasador de pistón | ★ | 2 |
19 | Pistón | ★ | 1 |
20 | Varilla de conexión | HL030300AV | 1 |
21 | Perno | ▲ | 5 |
22 | Arandela | 1 | |
23 | Excéntrica | 1 | |
24 | Condensador | ❋ | 1 |
24a | Condensador | ❋ | 1 |
25 | Arandela | ▼, ❋ | 4 |
26 | Tuerca | ❋ | 2 |
27 | Cubierta de la caja del cigüeñal | ▲ | 1 |
28 | Anillo en O | ❏ | 1 |
29 | Ventanilla | ❏ | 1 |
30 | Anillo en O | ❍ | 1 |
31 | Tapón del orificio de drenaje | ❍ | 1 |
32 | Anillo en O | ◆ | 1 |
33 | Respiradero | ◆ | 1 |
34 | Junta de la tapa de la caja |
|
|
| del cigüeñal | ● | 1 |
35 | Caja del cigüeñal | 1 | |
36 | Arandela | ▲ | 4 |
37 | Tornillo de la cubierta | ▲ | 4 |
38 | Sello del sistema de lubricación | 1 | |
39 | Cojinete | 1 | |
40 | Rotor | 1 | |
41 | Cojinete | 1 | |
42 | Estator | 1 | |
43 | Marco en campana del extremo |
|
|
| posterior del motor | 1 | |
44 | Sobrecarga térmica | 1 | |
44a | Anillo de orientación | 1 | |
44b | Separador | 1 | |
44c | Anillo de orientación | 1 | |
44d | Interruptor de arranque | 1 | |
44e | Tornillo | 2 | |
44f | Circlip | 1 | |
45 | Ventilador | ▼ | 1 |
46 | Circlip | ▼▼ | 1 |
47 | Arandela | 4 | |
48 | Arandela de seguridad | 4 | |
49 | Perno de motor | 4 | |
50 | Cordón del motor | 1 | |
51 | Cordón eléctrico | 1 | |
52 | Manómetro | HL030400AV | 2 |
53 | Valvula de chequeo | HL030500AV | 1 |
54 | Mango | HL030600AV | 1 |
55 | Manga | ✩ | 2 |
56 | Tuerca | ✩ | 2 |
57 | Tubo de escape | ✩ | 1 |
58 | Válvula de drenaje | HL030700AV | 1 |
59 | Tanque | 1 | |
60 | Perno | 2 | |
61 | Arandela | ◗ | 6 |
62 | Perno | ◗ | 4 |
63 | Base | 1 | |
64 | Pata | ◗ | 4 |
65 | Tapón | 1 | |
66 | Regulador de presión | HL030800AV | 1 |
67 | Niple de cierre | 1 | |
68 | Válvula de seguridad | HL030900AV | 1 |
69 | Presostato | HL031000AV | 1 |
70 | Manga | ✖ | 2 |
71 | Tuerca | ✖ | 2 |
72 | Tubo de descarga | ✖ | 1 |
JUEGOS DE PIEZAS PARA MANTENIMIENTO
▲Juego de cubierta (incluye 1
| y 4 cada uno de 36 y 37) | HL031100AV |
■ | Juego de culata (incluye 6 |
|
| y 4 cada uno de 4 y 5) | HL031200AV |
● | Juego de empaques |
|
| (incluye 7, 11, 14, 34) | HL031300AV |
◆ | Juego del plato de la válvula |
|
| (incluye 9 y 2 cada uno de 8 y 10) | HL031400AV |
▼ | Juego del cilindro |
|
| (incluye 2 cada uno de 13 y 25) | HL031500AV |
★Juego de pistones (incluye 15, 17, 19
y 2 cada uno de 16 y 18) | HL031600AV |
❋Juego del condensador (incluye 24, 24ª
y 2 cada uno de 25 y 26) | HL031700AV |
▲Juego de cubierta de la caja del cigüeñal
| (incluye 4 cada uno de 4 y 21) | HL031800AV |
❏ | Juego del visor de vidrio |
|
| (incluye 28 y 29) | HL031900AV |
❍ | Juego del tapón de drenaje |
|
| (incluye 30 y 31) | HL032000AV |
◆ | Juego de respiración (incluye 32 y 33) | HL032100AV |
▼ | Juego del ventilador (incluye 45 y 46) | HL032200AV |
✩Juego del tubo de escape
| (incluye 57 y 2 cada uno de 55 y 56) | HL032300AV |
◗ | Juego de pata (incluye 61, 62, y 64) | HL032400AV |
✖ | Juego de tubo de descarga |
|
| (incluye 70, 71, y 72) | HL032500AV |
6 | 27 Sp |
|