J. Routine Maintenance
NOTE: Units are to be inspected and serviced by qualified service personnel only.
1.Clean the unit air intake filter at least every 300 to 350 hours of operation. Clean the filters with a mild detergent in warm water and allow to dry thoroughly before reinstalling.
2.The indoor coil (evaporator coil), the outdoor coil (condenser coil) and base pan should be inspected periodically (yearly or
Before reinstalling the chassis in the sleeve, inspect the indoor blower housing, blower wheel, condenser fan blade, and condenser shroud periodically (yearly or
/antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser shroud. Use warm or cold water when rinsing these items. Allow the unit to dry thoroughly, inspect all gasket material for deterioration (replace as necessary), and then reinstall the chassis in the sleeve.
NOTE: Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser.
3.Periodically (at least yearly or
4.Inspect the surrounding area (inside and outside) to ensure that the units' clearances have not been compromised or altered.
5.Inspect the sleeve and drain system periodically (at least yearly or
6.Clean the front cover when needed. Use a mild detergent. Wash and rinse with warm water. Allow them to dry thoroughly before reinstalling them in the chassis.
Figure16
Components
| Condenser Fan Blade | Condenser Gasket | Outdoor Grille |
|
| ||
|
|
| |
| Indoor Blower | Condenser Shroud |
|
|
|
| |
| Discharge Air Grille |
|
|
Filters | Indoor Blower |
|
|
| Housing |
|
|
|
| Gasket |
|
|
| Compressor | Wall Sleeve |
| Front Cover | Basepan |
|
|
| Innerwall |
|
Return Air |
| Control Panel |
|
Grille |
| Evaporator Coil |
|