ADDITIONAL ACCESSORIES

MODEL NUMBER

DESCRIPTION

 

PHOTO

 

SLEEVE EXTENSION RETROFIT KIT G-90 zinc coated

 

PXSE

steel, 2.4" sleeve extension attached to the room side of the

 

sleeve to allow for the installation of a P-Series Friedrich

 

 

 

 

PTAC in a T-Series sleeve.

 

PXSE

 

 

 

 

LATERAL DUCT ADAPTER Attaches to the PTAC/PTHP

 

PDXDA

unit and provides a transition to direct up to 35% of the total

 

CFM to a secondary room, either left or right of the unit. Kit

 

 

includes duct plenum with discharge grille and internal baffle,

 

 

adapter and end cap.

 

 

 

LATERAL DUCT EXTENSION A three foot insulated

 

PDXDE

plenum that attaches to the left or right side of the duct

PDXDA

adapter. The extension can be cut to length by the installer.

 

 

 

Maximum allowable straight extension is fifteen feet.

 

PXDL

CONTROL DOOR LOCK KIT Locks control door to

 

prevent tampering by unauthorized users

 

 

 

 

 

 

PXDL

 

REPLACEMENT FILTER PACK

These are original

 

PDXFT

equipment return air filters. They are reusable and can be

 

cleaned by vacuuming, washing, or blowing out, and are sold

 

 

 

 

in convenient ten packs. (Two filters per chassis)

 

 

 

 

PDXFT

 

CONDUIT KIT WITH JUNCTION BOX Hard wire conduit kit

 

PXCJ

with junction box for 208/230V and 256V units (subbase not

 

required). Kit includes a means of quick disconnect for easy

 

 

 

 

removal of the chassis. *Required for 265V installations.

PXCJ

 

 

 

PXPC

POWER CORD RETROFIT Replaces LCDI power cord on 230V

 

models when unit is used with a subbase. PXPC15 is used with

 

15/20/30

15 amp 2.5 kW units. PXPC20 is used with 20 amp 3.4 kW

 

 

units. PXPC30 is used with 30 amp 5.0 kW units.

 

 

 

 

PXPC30

Mad

ein

 

 

FR

US

4548

 

 

321

A

CHASSIS OPTIONS

DESIGNATOR

DESCRIPTION

SSTANDARD UNIT Standard PTAC/PTHP chassis. Can be 230/208V or 265V, electric or heat pump.

SEACOAST PROTECTION Additional protection for PTAC/PTHP units in a coastal or corrosive

Cenvironment. The entire outdoor coil is submerged in a specially formulated enamel coating, then oven- cured for a tough, corrosion-resistant finish.

26

Image 26
Contents Ptac Standard Control Remote Thermostat Seacoast ProtectedTable of Contents Model Number Code Ptac Installation Recommendations Building ElevationFriedrich Digital Control Features DigitalTemperatureHeatPumpMode Internal Drain optional for new construction Installation Instructions PXDR10 Drain KitDrain Kit Location and Installation Cover Plate Installation ExternalDrainfor new construction or unit replacementDrain Tube Installation Drain Kit InstallationWall Sleeve Installation Instructions Pdxws TypicalWallSleeveInstallationDimensions LintelInstallationWall Sleeve Extension Sealant Locations Section II Deep Wall Installation PxweExtension Installation Installation Instructions Model Pxga Standard Grille Standard Grille15/20A Lcdi Device Power Cord Information 230/208V models onlyElectrical Rating Tables 30A Lcdi DeviceInstallation Checklist Section III Chassis InstallationWall sleeve Wall sleeve flange Chassis flange and gasket Digital Control User Input Configuration Dip Switch SettingFactory Dip Switch Configuration Digital Control Operation Control board with optional Pdxrt escutcheon kit installed Remote Thermostat and Low Voltage Control ConnectionsDesk Control Terminals Fresh Air Vent ControlAir Discharge Grille Auxiliary Fan ControlStart-up Checklist Appendix a Electrical Wiring for 265 Volt Models Line Voltage ConnectionsRoutine Maintenance ComponentsEnvironmental Effects Heating Mode Basic Troubleshooting TechniquesEnvironmental Effects Cooling Mode Insufficient Maintenance and InspectionTest Mode Digital Control Diagnostics and Test ModeDiagnostics Friedrich Ptac Accessories Pxdl Friedrich Air Conditioning Company 920-087-04