Product Overview
Front panel
av022a
1SETUP button - Push to scroll through the Setup menu screens. Press and hold for three seconds to save the current screen as the default screen.
2STATUS button - Push to scroll through the menu screens. Press and hold for 10 seconds to view the Diagnostic menu screens.
3LCD Display
4ON/OFF button - Push this button to apply power to the outlets. The unit will continue to provide surge protection when the unit is turned on or off.
5UP/DOWN buttons - Use the up and down buttons to scroll through options on the menu screens.
6Removable front bezel - The front bezel can be removed to connect the battery, or to replace the battery.
Rear panel
|
|
|
|
| CONTROLLED | Circuit Breaker |
|
|
|
|
| BY MASTER | |
|
|
|
|
| Push to Reset | |
|
|
|
|
|
| |
Cable |
| Cable |
| Battery Backup | Surge Only | Input 120 V- |
In |
| Out |
|
|
|
|
USB Tel/DVR/SAT/DSL | TVSS | MASTER | CONTROLLED BY MASTER |
| ||
|
|
| ||||
|
|
| GND |
|
| Building |
Data Port | In | To |
|
|
| Wiring Fault |
|
|
|
| |||
|
| Equipment |
|
|
|
|
1Coaxial surge protected, input and output connectors
2Battery Backup outlets with noise filtering; voltage regulation is available on the J35B model
3 Surge Protection outlets with noise filtering
4 Circuit breaker reset button
5 120 Vac input outlet, use with the supplied input power cord 6 Building wiring fault LED See “Troubleshooting” on page 9.
7TVSS ground screw. Use a wire to connect any ungrounded component to this screw. Connecting to the TVSS screw will prevent sound or video interference from ungrounded equipment.
8Telephone line surge protection, input and output connectors
9USB port for use with optional PowerChute® Personal Edition software, available as a free download at www.apc.com. In the event of a power outage, this software will save files and gracefully shut down the computer. Use the supplied USB cable to connect the UPS to the home computer.
:Surge Protection, Controlled by Master outlet, J35B models only.
; Controlled by Master outlets with Battery Backup, J35B models only. < Master outlet, J35B models only.
2 | A/V J Type Power Conditioner and Battery Backup |