RealTime Display Indications
•When the battery is being charged no remaining runtime is displayed.
•Remaining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery.
•If no load is detected, or if the battery is removed from the charger before any discharge load is applied, the default assumed power for remaining run time calculations is 20 Watts.
•When the battery determines that a load is attached, remaining run time will be calculated based on that load and the time remaining will be updated.
•The battery will “learn” this new load and retain that load information in
•OVERCURRENT INDICATION
If the battery is subjected to a load that exceeds specifications all status icons on the LCD will flash at a once per second rate. When the
•When the battery is completely discharged the LCD will flash the 15 minute icon until the battery is returned to a charger.