Freedom Inverter/Charger Configuration

Setting Battery Types on the Main Unit

You can attach different types of lead-acid batteries to the Freedom HF. Before installing batteries make sure that you configure the unit to optimize the charging process.

The settings can be changed by adjusting the dip switches found on the main unit behind the display panel.

To adjust the battery type setting:

By default the battery type is set to Flooded (OFFON).

1.Detach the Display Panel to expose the Dip Switches.

2.Use the tip of your fingernail or a small screw driver with a flat tip to adjust the switches.

Battery

Dip Switch Setting

Bulk/

 

 

 

 

 

 

 

 

 

Type

Switch 1Switch 2

Absorption

Float

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed

OFFOFF

13.5

13.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flooded

OFFON (default)

14.4

13.5

OFF

 

 

 

 

 

 

ON

GEL

ONOFF

14.2

13.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AGM

ONON

14.3

13.4

 

 

 

 

 

 

 

 

Switch 1 Switch 2

 

 

 

 

 

 

 

 

 

 

Figure 2 Dip Switches (Default Settings Shown)

 

975-0390-01-01

9

Image 23 Contents
Model Numbers Freedom HF Inverter/ChargersPage Document Part Number TrademarksDate and Revision Exclusion for DocumentationAudience About This GuidePurpose ScopeRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Precautions When Placing the Inverter/Charger Precautions When Preparing to ChargeRegulatory Precautions for Using Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page Materials List IntroductionKey Features Freedom HF 1800 T All Other Models Front Panel Freedom HF 1000, 1055 FeaturesDefault Setting Your Setting Feature DescriptionFront Panel Freedom HF 1055 EMS,1800 EMS Front Panel Freedom HF 1800 TRear Panel Freedom HF 1055 EMS,1800 EMS FeatureFreedom HF 1055 EMS,1800 EMS Remote and Power Module PanelSide Panel All Models Bulk Freedom Inverter/Charger ConfigurationSetting Battery Types on the Main Unit BatteryViewing Inverter/Charger Information Info and Setting LED Screen Info and Settings LEDSetting Adjusting Feature SettingsTo change the inverter mode setting To adjust the alarm setting Display Panel Operation Freedom Inverter/Charger OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Turning the Inverter Function On and Off Operating in Inverter ModeInverter Mode Setting is on Standby Inverter Mode Setting is OFFLED Status LED During Inverter ModeOperating Several Loads at Once Checking Battery StatusChecking Output Power Turning the Audible Alarm on or OFFTransitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModeInput Voltage Power OutputOperating Limits High Surge Loads Over-temperature ConditionsInverter Loads Overload ConditionsTrouble Loads Voltage Battery ChargingBattery Charging Batteries Routine MaintenanceFreedom HF Unit Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Charger Output Current vs. AC Input Voltage Battery Type Bulk/Absorption Volts Float VoltsPage Electrical Shock and Energy Hazard TroubleshootingTelevision Reception Common ProblemsBuzz in Audio Equipment  Error Code Condition Mode Action For error codes  to  Problem Possible Cause Solution Troubleshooting ReferenceTroubleshooting Reference OFF Problem Possible Cause Solution Long Transfer Times Inverter ApplicationsResistive Loads Motor LoadsFreedom HF 1000/1055 models Freedom HF 1800 models SpecificationsDC Input AC Input Warranty Warranty and Return InformationWarranty and Return Information Product DisclaimerReturn Procedure Return Material Authorization PolicyInformation About Your System Page Xantrex Technology USA Inc