Xantrex Technology 806-1020, 806-1055, 806-1840-01 manual Viewing Inverter/Charger Information

Page 24

Freedom Inverter/Charger Configuration

Viewing Inverter/Charger Information

The LED screen displays inverter/charger information as well as feature settings in coordination with the LED lights underneath the screen.

Press the Select button to toggle between the following information:

Info and Setting

LED Screen

Info and Settings LED

 

 

 

DC Input Voltage

.(example)

Solid – Input Voltage (V)

 

 

 

DC Input Current

(example)

Solid – Input Current (A)

 

 

 

AC Output Power

.(example)

Solid – Output Power (kW)

 

 

 

Charging Current

 or  or

none

Settinga



 

Charging Current

 or  or

none

Settingb

 or 

 

Charging Current

 or  or

none

Settingc

 or 

 

Inverter Mode Setting

 or 

none

 

 

 

Alarm Setting

 or 

none

 

 

 

Low Voltage Setting

 or 

none

 

 

 

a.Settings available only for Freedom HF 1000 (PN: 806-1020).

b.Settings available only for Freedom HF 1055 (PNs: 806-1055, 806-1055-02).

c.Settings available only for Freedom HF 1800 models (PNs: 806-1840, 806-1840-01, 806-1840-02).

10

Freedom HF Owner’s Guide

Image 24
Contents Freedom HF Inverter/Chargers Model NumbersPage Trademarks Date and RevisionExclusion for Documentation Document Part NumberAbout This Guide PurposeScope AudienceRelated Information Important Safety Instructions ReferenceFire and Burn Hazard Precautions When Working With Batteries Precautions When Preparing to Charge Precautions When Placing the Inverter/ChargerPrecautions for Using Rechargeable Appliances RegulatoryFCC Information to the User KKK Information to the UserPage Contents Page Introduction Materials ListKey Features Freedom HF 1800 T All Other Models Features Default Setting Your SettingFeature Description Front Panel Freedom HF 1000, 1055Front Panel Freedom HF 1800 T Front Panel Freedom HF 1055 EMS,1800 EMSFeature Rear Panel Freedom HF 1055 EMS,1800 EMSRemote and Power Module Panel Freedom HF 1055 EMS,1800 EMSSide Panel All Models Freedom Inverter/Charger Configuration Setting Battery Types on the Main UnitBattery BulkInfo and Setting LED Screen Info and Settings LED Viewing Inverter/Charger InformationAdjusting Feature Settings SettingTo change the inverter mode setting To adjust the alarm setting Freedom Inverter/Charger Operation Display Panel OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Operating in Inverter Mode Inverter Mode Setting is on StandbyInverter Mode Setting is OFF Turning the Inverter Function On and OffStatus LED During Inverter Mode LEDChecking Battery Status Checking Output PowerTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerPower Output Operating LimitsInput Voltage Over-temperature Conditions Inverter LoadsOverload Conditions High Surge LoadsTrouble Loads Battery Charging VoltageBattery Charging Routine Maintenance Freedom HF UnitBatteries Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Battery Type Bulk/Absorption Volts Float Volts Charger Output Current vs. AC Input VoltagePage Troubleshooting Electrical Shock and Energy HazardCommon Problems Buzz in Audio EquipmentTelevision Reception Error Code Condition Mode Action  For error codes  to  Troubleshooting Reference Problem Possible Cause SolutionTroubleshooting Reference OFF Problem Possible Cause Solution Inverter Applications Resistive LoadsMotor Loads Long Transfer TimesSpecifications Freedom HF 1000/1055 models Freedom HF 1800 modelsDC Input AC Input Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Return ProcedureInformation About Your System Page Xantrex Technology USA Inc
Related manuals
Manual 62 pages 35.03 Kb Manual 54 pages 4.84 Kb

806-1055-02, 806-1055, 806-1020, 806-1840-01, 806-1840 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.