Xantrex Technology 806-1055-02, 806-1020, 806-1840-01, 806-1840-02 manual Inverter Overload Operation

Page 41

Inverter Overload Operation

This graph shows how long (measured in milliseconds) the Freedom HF will operate for a given output current (measured in Amps).

Both the Freedom HF 1000/1055 models and Freedom HF 1800 models are represented in the illustration below.

The graph illustrates surge operation at 25 °C.

Time (ms)

4000

Freedom HF 1000/1055

 

Freedom HF 1800

 

 

 

 

 

 

 

 

 

 

 

 

1600

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

800

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

0

10

12

14

16

18

20

30

40

50

 

Output Current (amps)

975-0390-01-01

27

Image 41
Contents Model Numbers Freedom HF Inverter/ChargersPage Date and Revision TrademarksExclusion for Documentation Document Part NumberPurpose About This GuideScope AudienceRelated Information Reference Important Safety InstructionsFire and Burn Hazard Precautions When Working With Batteries Precautions When Placing the Inverter/Charger Precautions When Preparing to ChargeRegulatory Precautions for Using Rechargeable AppliancesKKK Information to the User FCC Information to the UserPage Contents Page Materials List IntroductionKey Features Freedom HF 1800 T All Other Models Default Setting Your Setting FeaturesFeature Description Front Panel Freedom HF 1000, 1055Front Panel Freedom HF 1055 EMS,1800 EMS Front Panel Freedom HF 1800 TRear Panel Freedom HF 1055 EMS,1800 EMS FeatureFreedom HF 1055 EMS,1800 EMS Remote and Power Module PanelSide Panel All Models Setting Battery Types on the Main Unit Freedom Inverter/Charger ConfigurationBattery BulkViewing Inverter/Charger Information Info and Setting LED Screen Info and Settings LEDSetting Adjusting Feature SettingsTo change the inverter mode setting To adjust the alarm setting Display Panel Operation Freedom Inverter/Charger OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Inverter Mode Setting is on Standby Operating in Inverter ModeInverter Mode Setting is OFF Turning the Inverter Function On and OffLED Status LED During Inverter ModeChecking Output Power Checking Battery StatusTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModeInput Voltage Power OutputOperating Limits Inverter Loads Over-temperature ConditionsOverload Conditions High Surge LoadsTrouble Loads Voltage Battery ChargingBattery Charging Batteries Routine MaintenanceFreedom HF Unit Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Charger Output Current vs. AC Input Voltage Battery Type Bulk/Absorption Volts Float VoltsPage Electrical Shock and Energy Hazard TroubleshootingTelevision Reception Common ProblemsBuzz in Audio Equipment  Error Code Condition Mode Action For error codes  to  Problem Possible Cause Solution Troubleshooting ReferenceTroubleshooting Reference OFF Problem Possible Cause Solution Resistive Loads Inverter ApplicationsMotor Loads Long Transfer TimesFreedom HF 1000/1055 models Freedom HF 1800 models SpecificationsDC Input AC Input Warranty Warranty and Return InformationWarranty and Return Information Product DisclaimerReturn Procedure Return Material Authorization PolicyInformation About Your System Page Xantrex Technology USA Inc
Related manuals
Manual 62 pages 35.03 Kb Manual 54 pages 4.84 Kb

806-1055-02, 806-1055, 806-1020, 806-1840-01, 806-1840 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.