Status LED During Inverter Mode

The following summarizes the behavior of the Status LED during Inverter mode.

Table 2 Status LED during Inverter Mode

Status

Display

 

LED

Screen

Condition

 

 

 

Solid

.

Select button is pressed to display Input

YELLOW

(where 12.8 is

Battery Voltage.

 

an example of

The Input Battery Voltage LED lights up.

 

battery

Value in display screen is shown as Volts.

 

voltage)

 

 

 

 

 



Select button is pressed to display Input

 

(where 11 is

Current.

 

an example of

The Input Current LED lights up.

 

current)

Value in display screen is shown as Amps.

 

 

 

 

.

Select button is pressed to display Output

 

(where 0.85 is

Power.

 

an example of

The Output Power LED lights up.

 

output power

Value in display screen is shown as

 

in Kilowatts)

Kilowatts.

 

 

 

 

through

Warning condition detected while AC

 



output power is still available.

 

 

See Table 1, “Error Codes Displayed on the

 

 

Display Panel Screen” on page 33.

 

 

 

Table 2 Status LED during Inverter Mode

Status

Display

 

LED

Screen

Condition

 

 

 

Solid RED

through

Fault condition detected and AC output

 



power is not available. The unit will sound

 

 

an alarm and will shutdown completely

 

 

within 30 seconds.

 

 

See Table 1, “Error Codes Displayed on the

 

 

Display Panel Screen” on page 33.

 

 

 

Off

Off

Inverter is OFF.

 

 

 

Off (or

.

No communication between the Freedom

Yellow)

 

HF and the Display Panel because the

 

 

battery voltage was too low to start the

 

 

Inverter.

 

 

 

18

Freedom HF Owner’s Guide

Image 32
Contents Freedom HF Inverter/Chargers Model NumbersPage Trademarks Date and RevisionExclusion for Documentation Document Part NumberAbout This Guide PurposeScope AudienceRelated Information Important Safety Instructions ReferenceFire and Burn Hazard Precautions When Working With Batteries Precautions When Preparing to Charge Precautions When Placing the Inverter/ChargerPrecautions for Using Rechargeable Appliances RegulatoryFCC Information to the User KKK Information to the UserPage Contents Page Introduction Materials ListKey Features Freedom HF 1800 T All Other Models Features Default Setting Your SettingFeature Description Front Panel Freedom HF 1000, 1055Front Panel Freedom HF 1800 T Front Panel Freedom HF 1055 EMS,1800 EMSFeature Rear Panel Freedom HF 1055 EMS,1800 EMSRemote and Power Module Panel Freedom HF 1055 EMS,1800 EMSSide Panel All Models Freedom Inverter/Charger Configuration Setting Battery Types on the Main UnitBattery BulkInfo and Setting LED Screen Info and Settings LED Viewing Inverter/Charger InformationAdjusting Feature Settings SettingTo change the inverter mode setting To adjust the alarm setting Freedom Inverter/Charger Operation Display Panel OperationFreedom Inverter/Charger Operation Operating in Shore Power Mode Operating in Inverter Mode Inverter Mode Setting is on StandbyInverter Mode Setting is OFF Turning the Inverter Function On and OffStatus LED During Inverter Mode LEDChecking Battery Status Checking Output PowerTurning the Audible Alarm on or OFF Operating Several Loads at OnceTransitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerInput Voltage Power OutputOperating Limits Over-temperature Conditions Inverter LoadsOverload Conditions High Surge LoadsTrouble Loads Battery Charging VoltageBattery Charging Batteries Routine MaintenanceFreedom HF Unit Inverter Overload Operation Invert Power Derating vs. Ambient Temperature Battery Type Bulk/Absorption Volts Float Volts Charger Output Current vs. AC Input VoltagePage Troubleshooting Electrical Shock and Energy HazardTelevision Reception Common ProblemsBuzz in Audio Equipment Error Code Condition Mode Action  For error codes  to  Troubleshooting Reference Problem Possible Cause SolutionTroubleshooting Reference OFF Problem Possible Cause Solution Inverter Applications Resistive LoadsMotor Loads Long Transfer TimesSpecifications Freedom HF 1000/1055 models Freedom HF 1800 modelsDC Input AC Input Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Return ProcedureInformation About Your System Page Xantrex Technology USA Inc
Related manuals
Manual 62 pages 35.03 Kb Manual 54 pages 4.84 Kb

806-1055-02, 806-1055, 806-1020, 806-1840-01, 806-1840 specifications

Xantrex Technology is renowned for its innovative power solutions, and among its extensive product lineup, the model numbers 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 stand out for their sophisticated features and reliable performance. These models are primarily designed to meet the diverse energy needs in off-grid, mobile, and backup power applications.

The Xantrex 806 family is characterized by its versatility and high efficiency. One of the standout features across these models is their pure sine wave inverter technology. This technology ensures that the power output closely mimics utility-provided electricity, making it safe to use with sensitive electronics such as computers and medical equipment. The clean, reliable power allows users to operate a variety of appliances without the risk of damaging electrical devices.

Another key characteristic is the ability of these inverters to provide a robust surge capability. This is crucial for starting up heavy equipment or appliances that require a higher initial power draw, such as refrigerators and air conditioners. Users can feel confident knowing that these inverters can handle demanding loads without compromising performance.

Scalability is also a notable feature of the Xantrex 806 models. Users can easily integrate multiple units to expand their power capacity, making them suitable for anything from small RVs to larger off-grid installations. The inverters include advanced communication features, allowing for easy monitoring and management of energy consumption via remote control systems.

Furthermore, these models incorporate user-friendly designs with features aimed at enhancing usability. For instance, the LED indicators provide real-time information about the operational status and battery levels, enabling users to quickly assess their power system’s performance.

Durability and reliability are critical considerations for any power solution, and the Xantrex 806 series meets these demands effectively. Built with high-quality materials, these inverters are designed to withstand the rigors of daily use in various environments, from remote camping sites to urban settings. With built-in safety features such as overload protection, short circuit protection, and thermal shutdown, they provide peace of mind for users.

In summary, the Xantrex Technology models 806-1840-02, 806-1840-01, 806-1020, 806-1055, and 806-1055-02 exemplify advanced engineering in power inverter technology. With their pure sine wave output, impressive surge capability, scalability, and durable construction, they offer reliable solutions for users seeking effective energy management in diverse applications.