Graco 24P822 important safety instructions Setup Screens, Setup Screen 1 Key

Page 16

Setup Screens

Setup Screens

Use the Setup screens to set control parameters for the motor. See

Screen Navigation and Editing, page 9 , for information on how to make selections and enter data.

Inactive fields are grayed-out on a screen.

Information displayed on the Setup screens corresponds to the Modbus Registers. See Appendix A - Modbus Variable Map, page 34.

NOTE: Before setting up profiles on Setup Screens 1–4, do the initial setup on Setup Screens 5–15. Screens 5–15 establish the configuration for your system and affect the displayed data.

Setup Screen 1

Use this screen to set the operating mode for a selected pump and profile.

Figure 14 Setup Screen 1

Setup Screen 1 Key

Enter the screen.

Pump selection — See Step 1.

Profile selection — See Step 2.

Pressure mode or Flow mode — See Step 3

Setting for Back Pressure Regulator — See Step 4.

Press to accept the selections.

This softkey is disabled by default, and only appears if the “Profile Lock” box is checked on Setup Screen 15, page 29. Press to activate the profile just edited.

Exit the screen.

16

3A2527D

Image 16
Contents Important Safety Instructions 24P822 E-Flo DC Control Module KitContents Install the Control Module InstallationControl Module Install Optional Accessory Kits Pressure Transducer KitCable Connection Adcm Cable Connections Adcm Port Connector Purpose NumberCan Cables Cable Part Description Module Screens OperationModule Keys Membrane Keys Icons Screen IconsInitial Setup Screen Navigation and EditingInitial Setup Setup and Edit Profiles RUN Screen MapScreen Map Run Screen Run ScreensRun Screen 1 Key Run Screen 2 Key Run Screen 3 KeyRun Screens Run Screens 5-8 Screen 5 shown3A2527D Setup Screen Setup ScreensSetup Screen 1 Key Set Back Pressure Regulator Setup Screen 2 Key Setup Screen 3 Key Setup Screen 4 Key Setup Screen 4 In Pressure ModePressure Mode Examples Flow Mode ExamplesSelect Jog Mode Setup Screen 5 KeySetup Screen 6 Key Setup Screen 7 KeySetup Screens 8 Setup Screens 8 and 9 KeySetup Screens 10 Setup Screens 10 and 11 Screen 10 shownSetup Screen 12 Key Select Local or Remote ControlSetup Screen 13 Key Select Desired Pressure UnitsSetup Screen 14 Key MM/DD/YY DD/MM/YY YY/MM/DDSetup Screen 15 Key Set the PasswordDisplay Applicable Blink Alarm or Description Error Code TroubleshootingCode WMC 24P822 Control Module Kit PartsPart Description Accessory Kits BPR Controller Kit Start/Stop Switch Kit 16U729Pressure Transducer Kit 24R050 Part Description QtyAppendix a Modbus Variable Map Modbus Variable Register Size AccessModbus Registers Alarm Bits Pump Alarms Word Event Type Event Code Event Name Display Alarms Word Bit Event Type Event Code Event Name Display Alarms WordPump Status and Control Bits Units Unit Type Units RegisterRegister value for Unit valuesAppendix B. Pump Control from a PLC 3A2527D Graco Standard Warranty Graco Information