Setup Screens
Setup Screen 2
Use this screen to set the maximum, target, and minimum fluid pressure for a selected pump and profile. In pressure mode, you will set a target fluid pressure. In flow mode, you will set a maximum fluid pressure. In either pressure or flow mode,
a minimum pressure may be set if desired. See Setup Screen 4, page 20, to specify how the system will respond if the pump begins to operate outside of the set boundaries.
Setup Screen 2 Key
Enter the screen.
Pump selection — See Step 1.
Profile selection — See Step 2.
Fluid pressure maximum— See Step 3.
Fluid pressure target — See Step 4.
Fluid pressure minimum — See Step 5.
Press to accept the selections.
This softkey is disabled by default, and only appears if the “Profile Lock” box is checked on Setup Screen 15, page 29. Press to activate the profile just edited.
Exit the screen.
1.For systems with multiple pumps and one display, select the desired pump (1 to 8), using the
2.Select the desired profile (1 to 4), using the
3.In flow mode, set the desired maximum pump fluid pressure, as a percentage of the maximum pressure of your pump. NOTE: The motor will not run if the profile does not have a maximum pressure setting. This field is not used in pressure mode.
4.In pressure mode, set the desired fluid pressure target as a percentage of the maximum pressure of your pump. This field is not used in flow mode.
NOTE: If closed loop pressure is enabled, the target pressure will be displayed as a pressure value rather than a percentage of maximum pressure. See Setup Screens 8 and 9, page 24 to enable closed loop pressure control.
5.If desired, set a minimum pump fluid pressure, as a percentage of the maximum fluid pressure of your pump.
18 | 3A2527D |