Setup Screens

Setup Screen 2

Use this screen to set the maximum, target, and minimum fluid pressure for a selected pump and profile. In pressure mode, you will set a target fluid pressure. In flow mode, you will set a maximum fluid pressure. In either pressure or flow mode,

a minimum pressure may be set if desired. See Setup Screen 4, page 20, to specify how the system will respond if the pump begins to operate outside of the set boundaries.

Setup Screen 2 Key

Enter the screen.

Pump selection — See Step 1.

Profile selection — See Step 2.

Fluid pressure maximum— See Step 3.

Fluid pressure target — See Step 4.

Fluid pressure minimum — See Step 5.

Press to accept the selections.

This softkey is disabled by default, and only appears if the “Profile Lock” box is checked on Setup Screen 15, page 29. Press to activate the profile just edited.

Exit the screen.

1.For systems with multiple pumps and one display, select the desired pump (1 to 8), using the pull-down menu.

2.Select the desired profile (1 to 4), using the pull-down menu.

3.In flow mode, set the desired maximum pump fluid pressure, as a percentage of the maximum pressure of your pump. NOTE: The motor will not run if the profile does not have a maximum pressure setting. This field is not used in pressure mode.

4.In pressure mode, set the desired fluid pressure target as a percentage of the maximum pressure of your pump. This field is not used in flow mode.

NOTE: If closed loop pressure is enabled, the target pressure will be displayed as a pressure value rather than a percentage of maximum pressure. See Setup Screens 8 and 9, page 24 to enable closed loop pressure control.

5.If desired, set a minimum pump fluid pressure, as a percentage of the maximum fluid pressure of your pump.

18

3A2527D

Image 18
Contents Important Safety Instructions 24P822 E-Flo DC Control Module KitContents Installation Install the Control ModuleControl Module Install Optional Accessory Kits Pressure Transducer KitAdcm Cable Connections Adcm Port Connector Purpose Number Cable ConnectionCan Cables Cable Part Description Operation Module ScreensModule Keys Membrane Keys Icons Screen IconsInitial Setup Screen Navigation and EditingInitial Setup Setup and Edit Profiles RUN Screen MapScreen Map Run Screens Run ScreenRun Screen 1 Key Run Screen 2 Key Run Screen 3 KeyRun Screens Run Screens 5-8 Screen 5 shown 3A2527D Setup Screens Setup ScreenSetup Screen 1 Key Set Back Pressure Regulator Setup Screen 2 Key Setup Screen 3 Key Setup Screen 4 Key Setup Screen 4 In Pressure ModePressure Mode Examples Flow Mode ExamplesSelect Jog Mode Setup Screen 5 KeySetup Screen 6 Key Setup Screen 7 KeySetup Screens 8 Setup Screens 8 and 9 KeySetup Screens 10 Setup Screens 10 and 11 Screen 10 shownSetup Screen 12 Key Select Local or Remote ControlSetup Screen 13 Key Select Desired Pressure UnitsSetup Screen 14 Key MM/DD/YY DD/MM/YY YY/MM/DDSetup Screen 15 Key Set the PasswordError Code Troubleshooting Display Applicable Blink Alarm or DescriptionCode WMC Parts 24P822 Control Module KitPart Description Pressure Transducer Kit 24R050 Accessory Kits BPR Controller KitStart/Stop Switch Kit 16U729 Part Description QtyModbus Variable Register Size Access Appendix a Modbus Variable MapModbus Registers Alarm Bits Pump Alarms Word Event Type Event Code Event Name Display Alarms Word Display Alarms Word Bit Event Type Event Code Event NamePump Status and Control Bits Register value for Units Unit TypeUnits Register Unit valuesAppendix B. Pump Control from a PLC 3A2527D Graco Standard Warranty Graco Information