Installation on FAA Deep Bases |
Installation method
Installation method
Deep Base Installation
Adapter ring Installation
With this installation method, the light fixture is mounted onto the steel base, in which the isolating transformer may be located.
For
To install the adapter ring, proceed as follow:
Step | Action |
1Clean the contact surfaces of the deep base and adapter ring.
2Put onto the contact layer of the base a layer of RTV106 (Siemens Airfield Solutions NC 7835.55.151 or equivalent.
3Mount the adapter ring onto the base and torque down the screws supplied with it. Refer to the table “Screws Overview” on page 44 for the tool to use, the torque to apply, and the eventual use of “Loctite” sealing compound.
Illustration | The illustrations below clarify the installations on FAA deep bases: |
|
|
|
|
| 12 in. | ||
|
|
|
|
|
|
|
|
1. | Light fitting | 4. | FAA deep base | 7. | Rubber grommet | 10. | Isolating transformer |
|
|
|
|
|
|
|
|
2. | Sealing resin | 5. | Secondary connector | 8. | Conduit | 11. | Primary connector |
|
|
|
|
|
|
|
|
3. | Adapter ring | 6. | Earthing lugs | 9. | Spacer | 12. | Screw, 3/8” or M10 |
|
|
|
|
|
|
|
|
NOTE: When using an
NOTE: For fixture replacement on an existing
2002 Siemens Airfield Solutions, Incorporated | 96A0266D | 14 |
All rights reserved | Issued 2/02 |
|