Hitachi C 10FR instruction manual Troubleshooting Guide, Symptom Possible Causes Corrective Action

Page 22

TROUBLESHOOTING GUIDE

WARNING

To avoid injury from an accidental start, turn the switch OFF and always remove the plug from the power source before making any adjustments.

Consult Hitachi Authorized Service Center if for any reason the motor will not run.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

 

 

 

 

 

Saw will not start

1.

Saw not plugged in

1.

Plug in saw

 

2.

Fuse blown or circuit breaker tripped

2.

Replace fuse or reset circuit breaker

 

3. Cord damaged

3. Have cord replaced by Hitachi Authorized

 

 

 

 

Service Center

 

 

 

 

 

Does not make accurate

1.

Positive stop not adjusted correctly

1.

Check blade with square and adjust

45° and 90° rip cuts

 

 

 

positive stop

 

2.

Tilt angle pointer not set accurately

2.

Check blade with square and adjust to

 

 

 

 

zero

 

 

 

 

 

Material pinched blade

1.

Rip fence not aligned with blade

1.

Check and adjust rip fence

when ripping

2.

Warped wood, edge against fence is not

2.

Select another piece of wood

 

 

straight

 

 

 

 

 

 

 

Material binds on splitter

1.

Splitter not aligned correctly with blade

1.

Check and align splitter with blade

 

 

 

 

 

Saw makes

1.

Dull blade

1.

Replace blade

unsatisfactory cuts

2.

Blade mounted backwards

2.

Turn the blade around

 

3.

Gum or pitch on blade

3.

Remove blade and clean with turpentine

 

 

 

 

and coarse steel wool

 

4.

Incorrect blade for work being done

4.

Change the blade

 

5.

Gum or pitch on blade causing erratic

5.

Clean table with turpentine and steel wool

 

 

feed

 

 

 

 

 

 

 

Material kicked back

1.

Rip fence out of adjustment

1.

Align rip fence with miter gauge slot

from blade

2.

Splitter not aligned with blade

2.

Align splitter with blade

 

3.

Feeding stock without rip fence

3.

Install and use rip fence

 

4.

Splitter not in place

4.

Install and use splitter (with guard)

 

5.

Dull blade

5.

Replace blade

 

6.

The operator letting go of material before

6.

Push material all the way past saw blade

 

 

it is past saw blade

 

before releasing work

 

7.

Miter angle lock knob is not tight

7.

Tighten knob

Blade does not raise or

1.

Sawdust and dirt in raising and tilting

1.

Brush or blow out loose dust and dirt

tilt freely

 

mechanisms

 

 

 

 

 

 

 

Blade does not come up

1.

Extension cord too light or too long

1.

Replace with adequate size cord

to speed

2.

Low house voltage

2.

Contact your electric company

 

 

 

 

 

Machine vibrates

1.

Saw not mounted securely to workbench

1.

Tighten all mounting hardware

excessively

2.

Bench on uneven floor

2.

Reposition on flat level surface Fasten to

 

 

 

 

floor if necessary

 

3.

Damaged saw blade

3.

Replace blade

 

 

 

 

 

Does not make accurate

1.

Miter gauge out of adjustment

1.

Adjust miter gauge

45° and 90° cross cuts

 

 

 

 

 

 

 

 

 

— 22 —

Image 22
Contents 10FR Hitachi Authorized Service Centers Motor SAW Product SpecificationsYES Power Tool Safety Check for Damaged or Loose PartsTable SAW Safety Extension Requirements Electrical Requirements and SafetyPower Supply Requirements Guidelines for Extension CordsTools Needed for Assembly Accessories and AttachmentsCarton Contents Unpacking Your Table SAW Know Your Table SAW Front of Table SawAssembly and Adjustments Keeping the Area Clean Installing and Changing the Blade Fig. H, I, J RIP Fence Fig. GBlade Guard Assembly Fig. K, L, M Installing Table Side Extensions Fig. NAdjusting Rear Table Extension Installing Table Side EXTENSIONS- contd Fig. OInstalling Rear Table Extension Fig. P RIP Fence Adjustment Fig. QStop RIP Fence Indicator Adjustment Fig. QAdjusting the 90 and 45 Positive Stops Fig. Q-1, Q-2, Q-3 Blade Tilt PointerAdditional blade adjustments Fig. S Blade Parallel to the Miter Gauge Groove Fig. R, SOperation Basic SAW OperationsCutting Operations Ripping Fig. WBevel Crosscutting Fig. Z Bevel RippingRipping Small Pieces Compound Miter Crosscutting Fig. AAMaking the side Mitering Fig. BBAuxiliary Fence Fig. CC-1 Making the base Putting it togetherMaintaining Your Table SAW MaintenanceLubrication Troubleshooting Guide Symptom Possible Causes Corrective ActionPush Stick Parts List for Schematic a Parts ListJOB Site Table SAW Model NO. C10FR JOB Site Table SAW Model NO. C10FR JOB Site Table SAW Model NO. C10FRPage Hitachi Koki Canada Co