| TROUBLESHOOTING | |
|
| |
Problem | Possible Solutions | |
Air Compressor does not start. | Make sure the ON/OFF Knob (86) is in its “ON” (up) position. | |
| Make sure the Power Cord/Plug (64) is undamaged and plugged into | |
| a working 120 volt, grounded, electrical outlet. | |
| Check to see if the Circuit Breaker (31) has “tripped”. If necessary, | |
| allow the Compressor to completely cool. Then, reset the Circuit | |
| Breaker. | |
| Pull the Safety Valve (67) to release air pressure from the Tank (50) | |
| to allow for easier starting. | |
| Make sure the Air Filter (85) is clean and not blocking air flow. | |
Air Compressor automatically | Check to see if the Circuit Breaker (31) has “tripped”. | |
shuts down. | If necessary, allow the Compressor to completely cool. Then, reset | |
| ||
| the Circuit Breaker. | |
| Make sure the Compressor is plugged into a dedicated circuit with | |
| no other items sharing the electrical outlet. | |
| Check to make sure the oil level in the Compressor is at its proper | |
| level to prevent overheating. | |
| Make sure the Air Filter (85) is clean and not blocking air flow. | |
Air Compressor does not build | Make sure the Drain Valve (59) is completely closed. | |
up adequate air pressure in its | Make sure the Safety Valve (67) is completely closed. | |
Tank. | ||
| ||
| Make sure the Air Outlet Valve (69) is completely closed. | |
| Make sure the Air Filter (85) is clean and not blocking air flow. | |
| Check all air fittings and connections for leaks. | |
Air Compressor does not pro- | Verify that this compressor is of sufficient capacity to provide ad- | |
vide required air pressure to the | equate airflow (CFM) to the tool. | |
pneumatic tool. | Make sure the Air Outlet Valve (69) is completely open. | |
| ||
| Increase air pressure to the pneumatic tool by turning the Pressure | |
| Regulator (70) clockwise. | |
| Check for obstructions, sharp bends, and leaks in the air hose con- | |
| necting the Compressor to the pneumatic tool. | |
| Check all air fittings and connections for leaks. | |
| Air requirement of the tool exceeds the compressor’s capacity. See | |
| CFM output on page 2. |
SKU 93351 | For technical questions, please call | Page 16 |