Bryant 550A warranty TOT Supplied, Unit Indoor CAP Enhance, Tdr† Tdr + Txv‡

Page 21

COMBINATION RATINGS Continued

 

 

 

 

 

SEER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FACTORY-

 

Bryant Gas

 

Bryant Gas

 

 

 

 

TOT.

SUPPLIED

 

Furnace or

 

Furnace or

 

 

UNIT

INDOOR

CAP.

ENHANCE-

Standard

Accessory

 

Accessory

Accessory

 

SIZE-SERIES

MODEL

BTUH

MENT

Rating

TDR†

 

TDR + TXV‡

Puron TXV‡

EER

 

*CD5PX060

59,000

TXV

13.00

 

11.05

 

CC5A/CD5AA060

56,000

NONE

 

12.50

10.65

 

CC5A/CD5AW060

58,000

NONE

 

12.50

10.90

 

CE3AA060

58,000

NONE

 

13.00

11.00

 

CK3BA060

58,000

NONE

 

12.50

10.95

 

CK5A/CK5BA060

58,000

NONE

 

12.50

10.95

 

CK5A/CK5BT060

58,000

NONE

 

12.50

10.95

 

CK5A/CK5BX060

59,000

NONE

 

13.00

11.10

 

CK5PA060

58,000

TXV

12.50

 

10.95

 

CK5PT060

58,000

TXV

12.50

 

10.95

 

CK5PX060

59,000

TXV

13.00

 

11.10

 

F(A,B)4BN(F,B,C)060

58,000

TDR

 

12.50

10.70

 

FB4BNB070

59,000

TDR

 

13.00

11.05

 

FC4CN(F,B)060

58,000

TDR&TXV

12.50

 

10.70

 

FC4CNB070

59,000

TDR&TXV

13.00

 

11.05

 

FE4ANB006

59,000

TDR&TXV

13.50

 

11.75

 

FG3AAA060

57,000

NONE

 

12.50

10.80

 

FK4DNB006

59,000

TDR&TXV

13.50

 

11.75

 

FV4BNB006

59,000

TDR&TXV

13.50

 

11.75

 

FX4BNB060

59,000

TDR&TXV

13.00

 

11.05

 

 

COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5AA060

56,000

TDR

 

12.50

10.75

 

CD5PX060

58,000

TDR&TXV

13.00

 

11.10

 

CE3AA060

58,000

TDR

 

13.00

11.10

 

CK3BA060

57,500

TDR

 

13.00

11.10

 

CK5A/CK5BA060

57,500

TDR

 

13.00

11.10

 

CK5A/CK5BT060

57,500

TDR

 

13.00

11.10

 

CK5A/CK5BX060

58,500

TDR

 

13.00

11.25

 

CK5PA060

57,500

TDR&TXV

13.00

 

11.10

 

CK5PT060

57,500

TDR&TXV

13.00

 

11.10

 

CK5PX060

58,500

TDR&TXV

13.00

 

11.25

 

 

COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5AA060

56,000

TDR

 

12.50

10.90

 

CD5PX060

58,000

TDR&TXV

13.00

 

11.30

 

CE3AA060

58,000

TDR

 

13.00

11.30

 

CK3BA060

57,500

TDR

 

13.00

11.25

 

CK5A/CK5BA060

57,500

TDR

 

13.00

11.25

060-H

CK5A/CK5BT060

57,500

TDR

 

13.00

11.25

 

CK5A/CK5BX060

58,500

TDR

 

13.00

11.40

 

CK5PA060

57,500

TDR&TXV

13.00

 

11.25

 

CK5PT060

57,500

TDR&TXV

13.00

 

11.25

 

CK5PX060

58,500

TDR&TXV

13.00

 

11.40

 

 

COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5AA060

56,000

TDR

 

13.00

11.00

 

CD5PX060

58,000

TDR&TXV

13.00

 

11.40

 

CE3AA060

58,000

TDR

 

13.00

11.40

 

CK3BA060

57,500

TDR

 

13.00

11.35

 

CK5A/CK5BA060

57,500

TDR

 

13.00

11.35

 

CK5A/CK5BT060

57,500

TDR

 

13.00

11.35

 

CK5A/CK5BX060

58,500

TDR

 

13.00

11.50

 

CK5PA060

57,500

TDR&TXV

13.00

 

11.35

 

CK5PT060

57,500

TDR&TXV

13.00

 

11.35

 

CK5PX060

58,500

TDR&TXV

13.00

 

11.50

 

 

COILS + 355MAV060080 VARIABLE-SPEED FURNACE

 

 

 

 

CK3BA060

57,500

TDR

 

12.50

10.70

 

CK5A/CK5BA060

57,500

TDR

 

12.50

10.70

 

CK5A/CK5BT060

57,500

TDR

 

12.50

10.70

 

CK5PA060

57,500

TDR&TXV

12.50

 

10.70

 

CK5PT060

57,500

TDR&TXV

12.50

 

10.70

 

 

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

 

 

CK3BA060

57,500

TDR

 

12.50

10.80

 

CK5A/CK5BA060

57,500

TDR

 

12.50

10.85

 

CK5A/CK5BT060

57,500

TDR

 

12.50

10.85

 

CK5PA060

57,500

TDR&TXV

12.50

 

10.85

 

CK5PT060

57,500

TDR&TXV

12.50

 

10.85

 

 

COILS + 355MAV060120 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5AA060

56,000

TDR

 

12.50

10.55

 

CK3BA060

57,500

TDR

 

12.50

10.90

 

CK5A/CK5BA060

57,500

TDR

 

12.50

10.95

 

CK5A/CK5BT060

57,500

TDR

 

12.50

10.95

 

CK5A/CK5BX060

58,500

TDR

 

13.00

11.05

 

CK5PA060

57,500

TDR&TXV

12.50

 

10.95

 

CK5PT060

57,500

TDR&TXV

12.50

 

10.95

 

CK5PX060

58,500

TDR&TXV

13.00

 

11.05

See notes on page 22.

—21—

Image 21
Contents 550A Unit Dimensions Minimum Mounting DimensionsSize UnitPiston Identification noElectrical SpecificationsSpecifications Required for LOW-AMBIENT LONG-LINE SEA Coast Description AccessoryRating Unit Size StandardCombination Ratings Coils + 315A,JAV066155 VARIABLE-SPEED Furnace EER030-F TDR CC5A/CD5AW042 Coils + 355MAV060080 VARIABLE-SPEED Furnace Coils + 355MAV060100 VARIABLE-SPEED FurnaceCoils + 355MAV060120 VARIABLE-SPEED Furnace FV4BNF005 Coils + 355MAV042040 VARIABLE-SPEED Furnace Coils + 355MAV042060 VARIABLE-SPEED FurnaceCoils + 355MAV042080 VARIABLE-SPEED Furnace CC5A/CD5AC048 14.00 11.95 CD5AA048 40,500 CC5A/CD5AW060 CC5A/CD5AA060 CK5PA060 46,500 TOT Supplied Unit Indoor CAP EnhanceTDR† TDR + TXV‡ Tested combination 550A024-G Outdoor Section With CC5A/CD5AA030 Indoor Section Detailed Cooling CapacitiesCoils + 355MAV042040 Variable Speed Furnace Coils + 315A,JAV066155 Variable Speed FurnaceCoils + 355MAV060080 Variable Speed Furnace Coils + 355MAV042060 Variable Speed FurnaceSection Size 550A030-F Outdoor Section With CC5A/CD5AA036 Indoor SectionCoils + 355MAV042040 Variable Speed Furnace 550A030-F,Outdoor Section With CC5A/CD5AA036 Indoor Section28.3 25.9 550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section22.4 26.5 20.9 036 See notes on 550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section Coils + 315A,JAV066155 Variable Speed Furnace Coils + 355MAV060080 Variable Speed Furnace 33.5 30.7 550A042-F Outdoor Section With CD5AA048 Indoor Section042 048 Detailed Cooling Capacities 550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section Coils + 355MAV060100 Variable Speed Furnace FC4CNB 550A060-H Outdoor Section With CD5PX060 Indoor SectionCondenser only Ratings SST Condenser Entering AIR Temperatures F550A024-G 550A030-F550A042-F 550A048-F550A060-H System Design Summary Page Page General Guide Specifications