Bryant 550A warranty Unit Size Standard, Rating

Page 7

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)

5.Crankcase Heater

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.

Usage Guideline:

Required in low ambient applications.

Required in long line applications.

Suggested in all commercial applications.

6.Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

7.Liquid-Line Solenoid Valve (LLS)

This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor oper- ation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration.

Note: When LLS is used with reciprocating compressors, Compressor Start Assist — Capacitor and Relay is required. Usage Guideline:

Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut off TXV can be used instead of an LLS in single flow air conditioner applications. See Long Line Application Guideline.

8.MotorMaster®—Low-Ambient Controller

A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –20°F (–28.9°C), it maintains condensing temperature at 100°F ±

10°F (37.8°C ± –12°C). Usage Guideline:

A MotorMaster®—Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor tem- peratures below 55°F (12.8°C).

Suggested for all commercial applications.

9.Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

10.Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline:

Suggested when unit is installed closer than 15 ft to quiet areas—bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft apart.

11.Support Feet

Four stick-on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.

Usage Guideline:

Suggested in the following applications:

Coastal installations.

Windy areas or where debris is normally circulating.

Rooftop installations.

For improved sound ratings.

12.Thermostatic Expansion Valve (TXV)

A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.

Note: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist — Capacitor and Relay is required. Usage Guideline:

Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications

Required for use on all zoning systems.

13.Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory..

A-WTD. SOUND POWER (dBA)

UNIT SIZE-

STANDARD

 

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

 

SERIES

RATING

125

250

500

1000

2000

4000

8000

024-G

72

61.0

60.5

63.5

66.5

63.0

57.0

49.5

030-F

70

57.5

60.0

64.0

66.0

62.0

58.5

53.5

036-F, G

72

58.5

60.5

65.0

65.0

62.0

59.0

52.5

042-F

72

55.5

62.5

66

65.5

63.5

62.0

55.5

048-F

76

62.0

67.5

70.0

69.5

67.5

66.0

60.5

060-H

78

66.0

68.0

71.5

72.5

70.5

65.0

59.5

NOTE: Tested in accordance with ARI standard 270.95. (Not listed with ARI.)

—7—

Image 7
Contents 550A Unit Dimensions Minimum Mounting DimensionsIdentification no UnitSize PistonElectrical SpecificationsSpecifications Required for LOW-AMBIENT LONG-LINE SEA Coast Description AccessoryRating Unit Size StandardCombination Ratings Coils + 315A,JAV066155 VARIABLE-SPEED Furnace EER030-F TDR CC5A/CD5AW042 Coils + 355MAV060100 VARIABLE-SPEED Furnace Coils + 355MAV060080 VARIABLE-SPEED FurnaceCoils + 355MAV060120 VARIABLE-SPEED Furnace FV4BNF005 Coils + 355MAV042060 VARIABLE-SPEED Furnace Coils + 355MAV042040 VARIABLE-SPEED FurnaceCoils + 355MAV042080 VARIABLE-SPEED Furnace CC5A/CD5AC048 14.00 11.95 CD5AA048 40,500 CC5A/CD5AW060 CC5A/CD5AA060 CK5PA060 46,500 Unit Indoor CAP Enhance TOT SuppliedTDR† TDR + TXV‡ Tested combination 550A024-G Outdoor Section With CC5A/CD5AA030 Indoor Section Detailed Cooling CapacitiesCoils + 355MAV042060 Variable Speed Furnace Coils + 315A,JAV066155 Variable Speed FurnaceCoils + 355MAV042040 Variable Speed Furnace Coils + 355MAV060080 Variable Speed FurnaceSection Size 550A030-F Outdoor Section With CC5A/CD5AA036 Indoor SectionCoils + 355MAV042040 Variable Speed Furnace 550A030-F,Outdoor Section With CC5A/CD5AA036 Indoor Section28.3 25.9 550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section22.4 26.5 20.9 036 See notes on 550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section Coils + 315A,JAV066155 Variable Speed Furnace Coils + 355MAV060080 Variable Speed Furnace 33.5 30.7 550A042-F Outdoor Section With CD5AA048 Indoor Section042 048 Detailed Cooling Capacities 550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section Coils + 355MAV060100 Variable Speed Furnace FC4CNB 550A060-H Outdoor Section With CD5PX060 Indoor Section550A030-F SST Condenser Entering AIR Temperatures FCondenser only Ratings 550A024-G550A048-F 550A042-F550A060-H System Design Summary Page Page General Guide Specifications