GUIDE SPECIFICATIONS
GENERAL
System Description
Quality Assurance
Unit will be rated in accordance with the latest standard of ARI Standard 210.
Unit will be certified for capacity and efficiency, and listed in the lastest ARI directory.
Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC.
Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have
Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061)
Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
PRODUCTS
Equipment
Factory assembled, single piece,
Unit Cabinet
Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.
Fans
Condenser fan will be
Condenser fan motors will be totally enclosed,
Shafts will be corrosion resistant.
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with
Compressor
Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration isolators.
Condenser Coil
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed.
Refrigeration Components
Refrigeration circuit components will include
Unit will be equipped with a
Operating Characteristics
The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F. The power consumption at full
load will not exceed _____ kW.
Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at
conditions of _____ CFM entering air temperature at the
air
The system will have a SEER of _____ Btuh/watt or greater at
DOE conditions.
Electrical Requirements
Nominal unit electrical characteristics will be _____ v, single
phase, 60 hz. The unit will be capable of satisfactory
Unit electrical power will be single point connection. Control circuit will be 24v.
Special Features
Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 550A.24.9
© 2004 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 | PRINTED IN U.S.A. Catalog No. |