Bryant 550A warranty Specifications, Electrical

Page 4

SPECIFICATIONS

UNIT SIZE-SERIES

024-G

 

030-F

 

036-F/G

Operating Weight (Lb)

214

 

202

 

237

 

 

 

 

 

 

 

 

ELECTRICAL

 

 

 

 

 

Unit Volts—Hertz—Phase

 

 

208/230—60—1

 

 

 

 

 

 

 

 

 

 

Operating Voltage Range*

 

 

187—253

 

 

 

 

 

 

 

 

 

 

Compressor— Rated Load Amps

12.8

 

14.7

 

15.4/16.7

 

 

 

 

 

 

 

 

 

 

Locked Rotor Amps

60.0

 

72.5

 

83.0/79.0

 

 

 

 

 

 

 

 

Condenser Fan Motor—Full Load Amps

0.80

 

0.80

 

1.1

 

 

 

 

 

 

 

 

Min Unit Ampacity for Wire Sizing

16.8

 

19.2

 

20.2/22.0

 

 

 

 

 

 

 

 

Min Wire Size (60°C Copper) AWG†

14

 

14

 

12

 

 

 

 

 

 

 

 

Min Wire Size (75°C Copper) AWG†

14

 

14

 

12

 

 

 

 

 

 

 

 

Max Wire Length (Ft) (60°C Copper)‡

46

 

41

 

62/57

 

 

 

 

 

 

 

 

Max Wire Length (Ft) (75°C Copper)‡

44

 

39

 

59/54

 

 

 

 

 

 

 

 

Max Branch Circuit Fuse or

 

 

 

 

 

Circuit Breaker Size (Amps)

25

 

30

 

30

 

 

 

 

 

 

 

 

COMPRESSOR & REFRIGERANT

 

 

 

 

 

Compressor— Type

 

 

Scroll

 

 

 

 

 

 

 

 

 

 

Temperature & Current Protection

 

 

Internal Line Break

 

 

 

 

 

 

 

 

 

 

Refrigerant— Type

 

 

Puron® (R-410A)

 

 

 

 

 

 

 

 

 

 

 

Amount (Lb)

5.50

 

6.00

 

6.88

 

 

 

 

 

 

 

 

CONDENSER COIL & FAN

 

 

 

 

 

Coil Face Area (Sq Ft)

12.2

 

12.2

 

15.2

 

 

 

 

 

 

 

 

Fins per In.—Rows—Circuits

25—1—2

 

25—1—2

 

25—1—2

 

 

 

 

 

 

 

 

Fan Motor—HP (PSC) & RPM

1/8 & 825

 

1/8 & 825

 

1/5 & 825

 

 

 

 

 

 

 

 

Volts—Hertz—Phase

 

 

208/230—60—1

 

 

 

 

 

 

 

 

 

 

Condenser Airflow (CFM)

2400

 

2400

 

2800

 

 

 

 

 

 

 

 

OPTIONAL EQUIPMENT

 

 

 

 

 

Support Feet

 

 

KSASF0101AAA

 

 

 

 

 

 

 

 

 

 

Coastal Filter

 

 

KAACF0801MED

 

 

Time Delay Relay

 

 

KAATD0101TDR

 

 

 

 

 

 

 

 

 

 

Cycle Protector

 

 

KSACY0101AAA

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

 

KAACH1201AAA

 

 

 

 

 

 

 

 

 

 

Start Assist—Capacitor/Relay Type

 

 

KSAHS1501AAA

 

 

 

 

 

 

 

 

 

Start Assist—PTC Type

Standard

 

 

KAACS0201PTC

 

 

 

 

 

 

 

 

TXV (Hard Shutoff)

KSATX0201PUR

 

 

KSATX0301PUR

 

 

 

 

 

 

 

 

Piston Body

 

 

KSAPX0101PIS

 

 

 

 

 

 

 

 

 

 

Filter Drier (Suction Line)

 

 

KH45LG140 (RCD)

 

 

 

 

 

 

 

 

 

 

Evaporator Freeze Thermostat**

 

 

KAAFT0101AAA

 

 

 

 

 

 

 

 

 

 

Liquid-Line Solenoid Valve

 

 

KAALS0201LLS

 

 

 

 

 

 

 

 

 

 

Winter Start Control**

 

 

KAAWS0101AAA

 

 

 

 

 

 

 

 

 

 

Low-Ambient Pressure Switch

 

 

KSALA0301410

 

 

 

 

 

 

 

 

 

 

MotorMaster® Low-Ambient Controller ††

 

 

KSALA0401AAA

 

 

 

 

 

 

 

 

 

 

Ball Bearing Fan Motor

 

 

HC38GE231 (RCD)

 

 

 

 

 

 

 

 

 

 

Thermidistat™ Control—

 

 

 

 

 

Programmable Thermostat with Humidity Control

 

 

TSTATBBPRH01-B

 

 

Thermostat—Auto Changeover,

 

 

 

 

 

7-Day Programmable, °F/°C,

 

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

 

TSTATBBPAC01-B

 

 

 

 

 

 

 

 

 

 

Thermostat—Auto Changeover,

 

 

 

 

 

Non-Programmable, °F/°C,

 

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

 

TSTATBBNAC01-C

 

 

Thermostat—Manual Changeover

 

 

 

 

 

5-2 Day Programmable, °F/°C,

 

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

 

TSTATBBSAC01

 

 

Builder’s Thermostat—Manual Changeover,

 

 

 

 

 

Non-Programmable, °F/°C,

 

 

 

 

 

1-Stage Heat, 1-Stage Cool

 

 

TSTATBBBAC01-B

 

 

 

 

 

 

 

 

 

 

Outdoor Air Temperature Sensor

 

 

TSTATXXSEN01-B

 

 

 

 

 

 

 

 

 

 

Backplate for Non-Programmable Thermostat

 

 

TSTATXXNBP01

 

 

 

 

 

 

 

 

 

 

Backplate for Programmable Thermostat

 

 

TSTATXXPBP01

 

 

 

 

 

 

 

 

 

 

Backplate for Builder’s Thermostat

 

 

TSTATXXBBP01

 

 

 

 

 

 

 

 

 

 

Backplate for Standard Thermostat

 

 

TSTATXXSBP01

 

 

 

 

 

 

 

 

 

 

Thermostat Conversion Kit (4 to 5 wire)—10 Pack

 

 

TSTATXXCNV10

 

 

 

 

 

 

 

 

 

 

Evolution Controls

 

 

See chart.

 

 

See notes on page 5.

.

—4—

Image 4
Contents 550A Dimensions Unit Dimensions Minimum MountingUnit SizePiston Identification noSpecifications ElectricalSpecifications Description Accessory Required for LOW-AMBIENT LONG-LINE SEA CoastUnit Size Standard RatingCombination Ratings EER Coils + 315A,JAV066155 VARIABLE-SPEED Furnace030-F TDR CC5A/CD5AW042 Coils + 355MAV060100 VARIABLE-SPEED Furnace Coils + 355MAV060080 VARIABLE-SPEED FurnaceCoils + 355MAV060120 VARIABLE-SPEED Furnace FV4BNF005 Coils + 355MAV042060 VARIABLE-SPEED Furnace Coils + 355MAV042040 VARIABLE-SPEED FurnaceCoils + 355MAV042080 VARIABLE-SPEED Furnace CC5A/CD5AC048 14.00 11.95 CD5AA048 40,500 CC5A/CD5AW060 CC5A/CD5AA060 CK5PA060 46,500 Unit Indoor CAP Enhance TOT SuppliedTDR† TDR + TXV‡ Tested combination Detailed Cooling Capacities 550A024-G Outdoor Section With CC5A/CD5AA030 Indoor SectionCoils + 315A,JAV066155 Variable Speed Furnace Coils + 355MAV042040 Variable Speed FurnaceCoils + 355MAV060080 Variable Speed Furnace Coils + 355MAV042060 Variable Speed Furnace550A030-F Outdoor Section With CC5A/CD5AA036 Indoor Section Section Size550A030-F,Outdoor Section With CC5A/CD5AA036 Indoor Section Coils + 355MAV042040 Variable Speed Furnace550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section 28.3 25.922.4 26.5 20.9 036 See notes on 550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section Coils + 315A,JAV066155 Variable Speed Furnace Coils + 355MAV060080 Variable Speed Furnace 550A042-F Outdoor Section With CD5AA048 Indoor Section 33.5 30.7042 048 Detailed Cooling Capacities 550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section Coils + 355MAV060100 Variable Speed Furnace 550A060-H Outdoor Section With CD5PX060 Indoor Section FC4CNBSST Condenser Entering AIR Temperatures F Condenser only Ratings550A024-G 550A030-F550A048-F 550A042-F550A060-H System Design Summary Page Page Guide Specifications General
Related manuals