EVOLUTION™* CONTROLS
|
| DESCRIPTION |
|
|
| ACCESSORY | ||
|
|
|
|
|
|
|
| |
Evolution Control Deluxe |
|
| SYSTXBBUID01 | |||||
|
|
|
|
|
|
| ||
| Evolution Zone Control Deluxe Zoning |
|
| |||||
Z |
| SYSTXBBUIZ01 | ||||||
O |
|
|
|
|
|
|
|
|
N | Evolution |
| SYSTXBB4ZC01 | |||||
I |
|
|
|
|
|
| ||
Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control |
| SYSTXBBSMS01 | ||||||
N | in an individual zone.) |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
G |
|
|
|
|
|
|
| |
Evolution Remote Room Sensor (Monitors temperature in an individual zone.) |
|
| SYSTXBBRRS01 | |||||
|
|
|
|
|
|
|
|
|
Evolution System Access Module (Hardware for wireless access and control via phone or |
|
| SYSTXBBSAM01 | |||||
internet.) |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||
Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators |
| SYSTXBBNIM01† | ||||||
or older |
|
| ||||||
|
|
|
| |||||
|
|
|
|
|
|
| ||
Back Plate for Evolution Control (Decorative wall plate.) |
|
| SYSTXXXBPU01 | |||||
|
|
|
|
|
|
| ||
* When applied with Bryant’s Perfect Humidity™ series 355, 315 and FE Indoor Models. |
|
| ||||||
† Must be installed in |
|
|
|
| ||||
|
|
| ACCESSORY USAGE GUIDELINE |
|
| |||
|
|
|
|
|
|
|
| |
|
|
| REQUIRED FOR |
| REQUIRED FOR |
| REQUIRED FOR | |
|
|
|
|
|
|
| SEA COAST | |
|
|
| APPLICATIONS |
| APPLICATIONS* |
| APPLICATIONS | |
| ACCESSORY |
| (Below 55°F) |
| (Over 50 Ft) |
| (Within 2 Miles) | |
|
|
|
|
|
|
|
|
|
| Crankcase Heater |
| Yes |
|
| Yes |
| No |
|
|
|
|
|
|
|
|
|
| Evaporator Freeze Thermostat |
| Yes |
|
| No |
| No |
|
|
|
|
|
|
|
|
|
| Winter Start Control |
| Yes† |
|
| No |
| No |
|
|
|
|
|
|
|
|
|
| Accumulator |
| No |
|
| No |
| No |
|
|
|
|
|
|
|
|
|
| Compressor Start Assist |
| Yes |
|
| Yes |
| No |
| Capacitor and Relay |
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
MotorMaster® |
|
|
|
|
|
|
| |
| or |
| Yes |
|
| No |
| No |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Wind Baffle |
| See |
|
| No |
| No |
|
|
|
|
|
|
|
|
|
| Coastal Filter |
| No |
|
| No |
| Yes |
|
|
|
|
|
|
|
|
|
| Support Feet |
| Recommended |
|
| No |
| Recommended |
|
|
|
|
|
|
|
| |
|
|
|
| See |
|
| ||
| or |
| No |
| Application |
| No | |
| Hard Shutoff TXV |
|
|
| Guideline |
|
| |
|
|
|
|
|
|
|
|
|
| Ball Bearing Fan Motor |
| Yes‡ |
|
| No |
| No |
|
|
|
|
|
|
|
|
|
*For tubing line sets greater than 50 ft horizontal and/or 20 ft vertical differential, refer to Residential
†Only when
‡ Required for MotorMaster® Control only.
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1.Ball-Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when
2.Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
3.Compressor Start Assist – Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line
Low ambient
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for scroll compressors in the following applications:
Long line
Low ambient
Suggested for all compressors in areas with a history of low voltage problems.
4.Compressor Start Assist — PTC Type
Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each
Usage Guideline:
Suggested in installations with marginal power supply.