EVOLUTION™* CONTROLS

 

 

DESCRIPTION

 

 

 

ACCESSORY

 

 

 

 

 

 

 

 

Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.)

 

 

SYSTXBBUID01

 

 

 

 

 

 

 

 

Evolution Zone Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a

 

 

Z

 

SYSTXBBUIZ01

O

multi-zone system.)

 

 

 

 

 

 

 

N

Evolution 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.)

 

SYSTXBB4ZC01

I

 

 

 

 

 

 

Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control

 

SYSTXBBSMS01

N

in an individual zone.)

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

Evolution Remote Room Sensor (Monitors temperature in an individual zone.)

 

 

SYSTXBBRRS01

 

 

 

 

 

 

 

 

 

Evolution System Access Module (Hardware for wireless access and control via phone or

 

 

SYSTXBBSAM01

internet.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators

 

SYSTXBBNIM01†

or older two-speed outdoor models to system.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Back Plate for Evolution Control (Decorative wall plate.)

 

 

SYSTXXXBPU01

 

 

 

 

 

 

 

* When applied with Bryant’s Perfect Humidity™ series 355, 315 and FE Indoor Models.

 

 

† Must be installed in Dual-Fuel Evolution system applications.

 

 

 

 

 

 

 

ACCESSORY USAGE GUIDELINE

 

 

 

 

 

 

 

 

 

 

 

 

 

REQUIRED FOR

 

REQUIRED FOR

 

REQUIRED FOR

 

 

 

LOW-AMBIENT

 

LONG-LINE

 

SEA COAST

 

 

 

APPLICATIONS

 

APPLICATIONS*

 

APPLICATIONS

 

ACCESSORY

 

(Below 55°F)

 

(Over 50 Ft)

 

(Within 2 Miles)

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

Yes

 

 

Yes

 

No

 

 

 

 

 

 

 

 

 

 

Evaporator Freeze Thermostat

 

Yes

 

 

No

 

No

 

 

 

 

 

 

 

 

 

 

Winter Start Control

 

Yes†

 

 

No

 

No

 

 

 

 

 

 

 

 

 

 

Accumulator

 

No

 

 

No

 

No

 

 

 

 

 

 

 

 

 

 

Compressor Start Assist

 

Yes

 

 

Yes

 

No

 

Capacitor and Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MotorMaster® Low-Ambient Controller

 

 

 

 

 

 

 

 

or

 

Yes

 

 

No

 

No

 

Low-Ambient Pressure Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wind Baffle

 

See Low-Ambient Instructions

 

 

No

 

No

 

 

 

 

 

 

 

 

 

 

Coastal Filter

 

No

 

 

No

 

Yes

 

 

 

 

 

 

 

 

 

 

Support Feet

 

Recommended

 

 

No

 

Recommended

 

 

 

 

 

 

 

 

 

Liquid-Line Solenoid Valve

 

 

 

See Long-Line

 

 

 

or

 

No

 

Application

 

No

 

Hard Shutoff TXV

 

 

 

Guideline

 

 

 

 

 

 

 

 

 

 

 

 

Ball Bearing Fan Motor

 

Yes‡

 

 

No

 

No

 

 

 

 

 

 

 

 

 

*For tubing line sets greater than 50 ft horizontal and/or 20 ft vertical differential, refer to Residential Split-System Long-Line Application Guideline and Service Manual.

Only when low-pressure switch is used.

‡ Required for MotorMaster® Control only.

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)

1.Ball-Bearing Fan Motor

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when low-ambient controller (full modulation feature) or MotorMaster®—Low-Ambient Controller is installed.

2.Coastal Filter

A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.

3.Compressor Start Assist – Capacitor and Relay

Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline:

Required for reciprocating compressors in the following applications:

Long line

Low ambient

Hard shut off expansion valve on indoor coil

Liquid line solenoid on indoor coil

Required for scroll compressors in the following applications:

Long line

Low ambient

Suggested for all compressors in areas with a history of low voltage problems.

4.Compressor Start Assist — PTC Type

Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each start-up.

Usage Guideline:

Suggested in installations with marginal power supply.

—6—

Image 6
Contents 550A Dimensions Unit Dimensions Minimum MountingPiston UnitSize Identification noSpecifications ElectricalSpecifications Description Accessory Required for LOW-AMBIENT LONG-LINE SEA CoastUnit Size Standard RatingCombination Ratings EER Coils + 315A,JAV066155 VARIABLE-SPEED Furnace030-F TDR CC5A/CD5AW042 Coils + 355MAV060080 VARIABLE-SPEED Furnace Coils + 355MAV060100 VARIABLE-SPEED FurnaceCoils + 355MAV060120 VARIABLE-SPEED Furnace FV4BNF005 Coils + 355MAV042040 VARIABLE-SPEED Furnace Coils + 355MAV042060 VARIABLE-SPEED FurnaceCoils + 355MAV042080 VARIABLE-SPEED Furnace CC5A/CD5AC048 14.00 11.95 CD5AA048 40,500 CC5A/CD5AW060 CC5A/CD5AA060 CK5PA060 46,500 TOT Supplied Unit Indoor CAP EnhanceTDR† TDR + TXV‡ Tested combination Detailed Cooling Capacities 550A024-G Outdoor Section With CC5A/CD5AA030 Indoor SectionCoils + 355MAV060080 Variable Speed Furnace Coils + 315A,JAV066155 Variable Speed FurnaceCoils + 355MAV042040 Variable Speed Furnace Coils + 355MAV042060 Variable Speed Furnace550A030-F Outdoor Section With CC5A/CD5AA036 Indoor Section Section Size550A030-F,Outdoor Section With CC5A/CD5AA036 Indoor Section Coils + 355MAV042040 Variable Speed Furnace550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section 28.3 25.922.4 26.5 20.9 036 See notes on 550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section Coils + 315A,JAV066155 Variable Speed Furnace Coils + 355MAV060080 Variable Speed Furnace 550A042-F Outdoor Section With CD5AA048 Indoor Section 33.5 30.7042 048 Detailed Cooling Capacities 550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section Coils + 355MAV060100 Variable Speed Furnace 550A060-H Outdoor Section With CD5PX060 Indoor Section FC4CNB550A024-G SST Condenser Entering AIR Temperatures FCondenser only Ratings 550A030-F550A042-F 550A048-F550A060-H System Design Summary Page Page Guide Specifications General