Porter-Cable PCB270TS Electrical Requirements and Safety, Power Supply and Motor Specifications

Page 7

ELECTRICAL REQUIREMENTS AND SAFETY

POWER SUPPLY AND MOTOR SPECIFICATIONS

!WARNING

To avoid electrical hazards, fire hazards, or damage to the tool, use proper circuit protection. Use a seperate electrical circuit for your tool. Your saw is wired at the factory for 120 V operation. Connect to a 120 V, 15 Amp circuit and use a 15 Amp time delay fuse or circuit breaker. To avoid shock or fire, if power cord is worn, cut, or damaged in any way, have it replaced immediately.

GROUNDING INSTRUCTIONS

!WARNING

This tool must be grounded while in use to protect the operator from electrical shock.

IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides a path of least resistance for electric currents and reduces the risk of electric shock. This tool is equipped with an electrical cord that has an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching receptacle that is properly installed and grounded in accordance with all local codes and ordinances.

DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the receptacle, have the proper receptacle installed by a qualified electrician.

IMPROPER CONNECTION of the equipment grounding conductor can result in risk of electric shock. The conductor with the green insulation (with or without yellow stripes) is the equipment grounding conductor.

If repair or replacement of the electrical cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.

CHECK with a qualified electrician or service person if you do not completely understand the grounding instructions, or if you are not certain the tool is properly grounded.

USE only 3-wire extension cords that have three-pronged grounding plugs with three-pole receptacles that accept the tool’s plug. Repair or replace damaged or worn cords immediately.

Use a separate electrical circuit for your tool. This circuit must not be less than #14 wire and should be protected with a 15 Amp time lag fuse. Before connecting the motor to the power line, make sure the switch is in the off position and the electric current is rated the same as the current stamped on the motor nameplate. Running at a lower voltage will damage the motor.

GUIDELINES FOR EXTENSION CORDS

USE THE PROPER EXTENSION CORD. Make sure your extension cord is in good condition. Use an extension cord heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power, overheating

and burning out of the motor. The table below shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Make sure your extension cord is properly wired and in good condition. Always replace a damaged extension cord or have it repaired by a qualified technician before using it. Protect your extension cords from sharp objects, excessive heat and damp or wet areas.

MINIMUM GAUGE FOR EXTENSION CORDS (AWG)

Ampere Rating

 

Total length of Cord

 

 

 

 

 

 

 

 

 

More Than

Not More Than

120V

25

50

100

150

ft.

 

 

 

(7.62

15.24

30.48

45.72

m)

 

 

240V

50

100

200

300

ft.

 

 

 

(15.24 30.48 60.96 91.44 m)

 

 

 

 

 

 

 

AWG - American Wire Gauge

 

 

 

 

 

 

 

 

0

6

 

18

16

16

14

 

 

 

 

 

 

 

 

 

6

10

 

18

16

14

12

 

 

 

 

 

 

 

 

 

10

12

 

16

16

14

12

 

 

 

 

 

 

 

12

16

 

14

12

Not Recommended

 

 

 

 

 

 

 

 

!WARNING

This tool is for indoor use only. Do not expose to rain or use in damp locations.

This tool is intended for use on a circuit that has a receptacle like the one illustrated in Fig. 1. Fig. 1 shows a three-pronged electrical plug and receptacle that has a grounding conductor. If a properly grounded receptacle is not available, an adapter (Fig. 2) can be used to temporarily connect this plug to a two-contact grounded receptacle. The adapter (Fig. 2) has a rigid lug extending from it that MUST be connected to a permanent earth ground, such as a properly grounded receptacle box.

!CAUTION

In all cases, make certain the receptacle is properly grounded. If you are not sure, have a qualified electrician check the receptacle.

Fig. 1

Three-Pronged Plug

 

Grounding Prong

Properly Grounded

Three-Pronged Receptacle

Fig. 2

Grounding Lug

Make sure this is connected to a known ground.

Two-Pronged

Adapter Receptacle

– 7 –

Image 7
Contents Advertencia Léase Este Table of Contents Support and Clamp Work ProhibitionGeneral Safety Instructions Before Using this Power Tool Power Tool SafetyTable SAW Safety Kickbacks Guidelines for Extension Cords Electrical Requirements and SafetyPower Supply and Motor Specifications Grounding InstructionsSupplied Not Supplied Volt Single Phase OperationCarton Contents Unpacking Your Table SAW Know Your Table SAW Glossary of Terms Assembling Stand FIG. A~I Assembly and AdjustmentsMoving Table SAW and Stand FIG. J Assembling Table SAW to Stand FIG. JAnti-kickback pawl storage Fig. L Storage FIG. L ~ RRiving knife storage Fig. P Fig. P Miter gauge storage Fig. Q Power cord storage Fig. RBlade Elevation Handwheel FIG Installing a Blade FIG. WAdjusting the 90 and 45 Positive Stops FIG. X, Y, Z Blade Tilting Handwheel FIGStop Fig. X, Y 45º Stop Fig. X, Z Blade Tilting Indicator FIG. AAFig. BB Fig. EE Installing Blade Guard Assembly FIG. FF, GGRIP Fence Adjustment FIG. JJ Installing the Miter GaugeAdjusting the Miter Gauge FIG. HH Installing the RIP Fence FIGFig. KK Basic SAW Operations OperationBevel Ripping Setting Bevel Angle FIG. QQCutting Operations Ripping FIG. PPRipping Small Pieces Using Wood Facing on the Miter GaugeCrosscutting FIG. RR Bevel Crosscutting FIG. TT Using Wood Facing on the RIP Fence FIG. WWMiter Cuts FIG Dado Cuts FIG 240V Operation Changing Wires FIG. YY, ZZFig. ZZ Lubrication MaintenanceGeneral Maintenance Maintaining Your Table SAWReplacement Parts Service and Repairs Troubleshooting GuideProblem Possible Causes Corrective Action Accessories Accessories and Attachments2WHW Dado Insert Plate Push Stick Construction Push Stick PatternMM Stationary Table SAW Parts List for Table SAW Parts ListMM Table SAW Schematic for Table SAW Description Size Qty MM Stationary Table SAW Parts List & Schematic for StandTerminal MM Stationary Table SAW Parts List & Schematic for MotorPage Three Year Limited Warranty Warranty