Porter-Cable CPLDC2540S instruction manual Hazard, Risk of Explosion or Fire

Page 3

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

HAZARD

RISK OF EXPLOSION OR FIRE

WHAT CAN HAPPEN

IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH

TO SPARK.

IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH

FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.

RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE

FIRE.

UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT IN PERSONAL

INJURY OR PROPERTY DAMAGE. TO REDUCE THE RISK OF FIRE, DO NOT ALLOW THE COMPRESSOR TO OPERATE UNATTENDED.

HOW TO PREVENT IT

ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED AREA FREE OF

COMBUSTIBLE MATERIALS, GASOLINE OR SOLVENT VAPORS.

IF SPRAYING FLAMMABLE MATERIALS,

LOCATE COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED.

STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COMPRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR. OPERATE COMPRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS.

OPERATE COMPRESSOR IN A CLEAN, DRY, WELL VENTILATED AREA. DO NOT OPERATE

UNIT INDOORS OR IN ANY CONFINED AREA.

ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT WHEN IT IS OPERATING.

ALWAYS DISCONNECT ELECTRICAL POWER BY MOVING PRESSURE SWITCH LEVER TO THE OFF POSITION AND DRAIN TANK DAILY OR AFTER EACH USE.

3- ENG

A02250

Image 3
Contents CPLDC2540S ManualImportant Safety Instructions Safety Guidelines DefinitionsRisk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk of Burns Risk from Moving PartsRisk of Falling Hazard Risk of Unsafe Operation CPLDC2540S SpecificationsGlossary Duty CycleAccessories AssemblyTo Add Oil To Pump Improper Grounding can Result in Electrical Shock InstallationLocation of the Air Compressor Allow the Compressor to GET WET Grounding InstructionsVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationMotor Thermal Overload Protector not shown Before StartingBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesOil CheckingMotor Air Filter Inspection and ReplacementTo Replace or Clean Check Valve Service and AdjustmentsStorage Problem Cause Correction TroubleshootingPressure reading Problem Cause Correction Problem Cause Correction This Warranty is not Transferable and does not Cover Limited Warranty