Porter-Cable CPLC7060V instruction manual Voltage and Circuit Protection, Lubrication and Oil

Page 10

Voltage and Circuit Protection

Refer to the Specifications for the voltage and circuit protection requirements of your air compressor. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the air compressor is connected to a circuit protected by fuses, use only dual element time delay fuses, as noted in the Specifications.

This product should be connected to a grounded, metallic, permanent wiring system, or an equipment-grounding terminal or lead on the product.

Typical schematic subject to all changes as dictated by local electrical codes and authorities.

Fig. 4

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK! In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric

current. This air compressor must be properly grounded.

Improper grounding can result in electrical shock! All grounding should be performed by a licensed electrician in

accordance with national and local electrical codes!

Make certain that the electrical circuit to which the air compressor is connected provides proper electrical grounding, correct voltage and adequate fuse protection. The air compressor can be grounded by the following method:

When hard wiring an air compressor, use wiring that contains a bare copper grounding wire. This wire must be connected to the pressure switch at the grounding location provided. This is located inside the pressure switch. The other end of the wire must be connected to a ground at the fuse/circuit breaker box in accordance with national and local electrical codes.

If these grounding instructions are not completely understood, or if you are in doubt as to whether the air compressor is properly grounded, have the installation checked by an Authorized Warranty Service Center or a licensed electrician.

Lubrication and Oil

Air compressors are shipped without oil. A small

amount of oil may be present in the pump upon receipt of the air compressor. This is due to plant testing and does not mean that the pump contains the correct amount of oil. Do not attempt to operate in order to check wiring or for any reason without first adding oil to the crankcase. Serious damage to the pump can result from even very limited use without oil. Fill crankcase with recommended oil before operating.

Multi-viscosity motor oils like 10W30, should not be used in an air compressor. They leave carbon deposits on critical components, thus reducing performance and air compressor life. Use air compressor oil only.

10-ENG

Image 10
Contents Single-Stage Oillube Important Safety Instructions Safety Guidelines DefinitionsRead and Follow ALL Instructions Hazard Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT Risk of BurstingRisk to Breathing What can Happen HOW to Prevent IT Risk from Flying Objects What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of Falling What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Burns What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorDuty Cycle SpecificationsGlossary CPLC7060V Pressure Switch B Description of OperationLocation of the Air Compressor InstallationAir Compressor Anchoring Methods Fig Wiring Instructions Fig Voltage and Circuit Protection Lubrication and OilAdditional Regulators and Controls PipingTypical Compressed Air Distribution System BREAK-IN Procedures Operating ProceduresMaintenance Routine Maintenance ScheduleService Instructions Safety Valve Inspection and Replacement Fig Check Valve Inspection and ReplacementBelt Replacement Pressure Switch Replacement Belt Guard Removal and InstallationAdjusting Belt Tension Motor Overload Protector ResetServicing Intake and Exhaust Valves Storage of Compressor Unit Troubleshooting Guide OVER-TIGHTENProblem Cause Correction Not Overtighten22-ENG Infrequently and is oversized for Accessories FILTERS, REGULATORS, Lubricators25-ENG Limited Warranty This Warranty is not Transferable and does not Cover