Porter-Cable CPLC7060V instruction manual BREAK-IN Procedures, Operating Procedures

Page 13

BREAK-IN PROCEDURES

This procedure is required before the air compressor is put into service, before the hose is installed, the check valve is replaced, or a complete compressor pump is replaced.

Serious damage may result if the following break-in instructions are not closely followed.

The procedure:

1.Make sure the pressure switch lever is in the "OFF" position.

2.Check air compressor wiring. Make sure wires are secure at all terminal connections. Free all contacts of loose wire cuttings, ect.

3.Open the drain valve fully to permit air to escape and prevent air pressure build- up in the air tank during the break-in period.

4.Move the pressure switch lever to "ON/AUTO". The compressor will start.

5.Run the air compressor for 30 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 30 minutes move the pressure switch lever to the OFF position, check oil and add if necessary.

7.Close the drain valve.

8.Move the pressure switch lever to "ON/AUTO". The air receiver will fill to cut- out pressure and the motor will stop.

Your air compressor is now ready for use.

OPERATING PROCEDURES

Daily Start-Up Checklist

1.Check oil and add if necessary.

2.Before attaching an air hose or accessory, make sure the shut-off valve is in the closed position. Make sure the ON/AUTO lever is in the OFF position.

Compressed air from the unit may contain water condensation and oil mist. Do not spray unfiltered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read instructions for air tool or device.

3.Attach regulator, hose and accessory. On models without an air pressure regulator, one must be installed before using accessories rated at less than 135 psig.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

4.Place the pressure switch lever in the ON-AUTO position. The motor will stop when air tank pressure reaches "cut-out pressure".

5.Open the shut-off valve.

6.If an air pressure regulator is in use, open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. Your unit is ready for use.

When You Are Finished:

7.Turn the air compressor unit off.

8.Turn the regulator counterclockwise and set the outlet pressure to zero.

9.Remove the air tool or accessory.

13-ENG

Image 13
Contents Single-Stage Oillube Important Safety Instructions Safety Guidelines DefinitionsRead and Follow ALL Instructions What can Happen HOW to Prevent IT Risk of Explosion or Fire What can Happen HOW to Prevent ITHazard Risk of BurstingRisk to Breathing What can Happen HOW to Prevent IT Risk from Flying Objects What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of Burns What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Falling What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorGlossary SpecificationsDuty Cycle CPLC7060VDescription of Operation Pressure Switch BLocation of the Air Compressor InstallationAir Compressor Anchoring Methods Fig Wiring Instructions Fig Lubrication and Oil Voltage and Circuit ProtectionPiping Additional Regulators and ControlsTypical Compressed Air Distribution System Operating Procedures BREAK-IN ProceduresRoutine Maintenance Schedule MaintenanceService Instructions Safety Valve Inspection and Replacement Fig Check Valve Inspection and ReplacementBelt Replacement Adjusting Belt Tension Belt Guard Removal and InstallationPressure Switch Replacement Motor Overload Protector ResetServicing Intake and Exhaust Valves Storage of Compressor Unit OVER-TIGHTEN Troubleshooting GuideNot Overtighten Problem Cause Correction22-ENG Infrequently and is oversized for FILTERS, REGULATORS, Lubricators Accessories25-ENG This Warranty is not Transferable and does not Cover Limited Warranty