Porter-Cable CPLC7060V instruction manual Check Valve Inspection and Replacement, Belt Replacement

Page 16

Check Valve - Inspection and Replacement

Remove and inspect the check valve at least once a year or more often if the air compressor is heavily used. Moisture and other contaminants in the hot compressed air will cause an accumulation of a carbon-like residue on the working parts. If the valve has heavy carbon build-up, it should be replaced. Use the following procedure to inspect, clean or replace the check valve.

1.Turn air compressor off and disconnect or lock out power source.

2.Release air pressure from the air tank.

3.Loosen the top and bottom tube nuts and remove the outlet tube.

4.Remove pressure release tube.

5.Unscrew the check valve.

6.Check that the valve disc moves freely and that the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent.

7.Apply sealant to the check valve threads. Reinstall the check valve. Do not overtighten.

8.Replace the outlet tube and tighten top and bottom nuts.

9.Replace pressure release tube.

10.Perform the Break-in procedure.

Safety Valve - Inspection and Replacement (Fig. 6)

IF THE SAFETY VALVE DOES NOT WORK PROPERLY, OVER-PRESSURIZATION MAY OCCUR CAUSING AIR TANK RUPTURE OR EXPLOSION. OCCASIONALLY PULL THE RING ON THE SAFETY VALVE TO MAKE SURE THAT THE SAFETY VALVE OPERATES FREELY. IF THE VALVE IS STUCK OR DOES NOT OPERATE SMOOTHLY, IT MUST BE REPLACED WITH A VALVE HAVING THE SAME PRESSURE RATING.

1.Remove and lock out power from the air compressor. Release any air pressure from the air tank.

2.Remove safety valve and replace with valve of the same pressure rating.

3.Apply thread sealant to new safety valve and tighten. DO NOT OVERTIGHTEN.

SAFETY VALVE

Fig. 6

Belt - Replacement

SERIOUS INJURY OR DAMAGE MAY OCCUR IF PARTS OF THE BODY OR LOOSE ITEMS GET CAUGHT IN MOVING PARTS. NEVER OPERATE THE UNIT WITH THE BELT GUARD REMOVED. THE BELT GUARD SHOULD BE REMOVED ONLY WHEN THE AIR COMPRESSOR POWER IS DISCONNECTED.

1.Remove and lock out power from the compressor.

2.Remove beltguard screws and beltguard.

3.Remove belt and replace.

16-ENG

Image 16
Contents Single-Stage Oillube Important Safety Instructions Safety Guidelines DefinitionsRead and Follow ALL Instructions Risk of Explosion or Fire What can Happen HOW to Prevent IT What can Happen HOW to Prevent ITHazard Risk of BurstingRisk to Breathing What can Happen HOW to Prevent IT Risk from Flying Objects What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent IT Risk of Burns What can Happen HOW to Prevent ITRisk of Falling What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorSpecifications GlossaryDuty Cycle CPLC7060VPressure Switch B Description of OperationLocation of the Air Compressor InstallationAir Compressor Anchoring Methods Fig Wiring Instructions Fig Voltage and Circuit Protection Lubrication and OilAdditional Regulators and Controls PipingTypical Compressed Air Distribution System BREAK-IN Procedures Operating ProceduresMaintenance Routine Maintenance ScheduleService Instructions Safety Valve Inspection and Replacement Fig Check Valve Inspection and ReplacementBelt Replacement Belt Guard Removal and Installation Adjusting Belt TensionPressure Switch Replacement Motor Overload Protector ResetServicing Intake and Exhaust Valves Storage of Compressor Unit Troubleshooting Guide OVER-TIGHTENProblem Cause Correction Not Overtighten22-ENG Infrequently and is oversized for Accessories FILTERS, REGULATORS, Lubricators25-ENG Limited Warranty This Warranty is not Transferable and does not Cover
Related manuals
Manual 24 pages 11.12 Kb