Bryant 577D----A installation instructions Observe all warnings, cautions, and bold text

Page 37

AIR CONDITIONER WITH PURON

REFRIGERATION SECTION QUICK-REFERENCE GUIDE

Puron refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with Puron. Puron refrigerant cylinders are rose colored.

SPuron refrigerant cylinders manufactured prior to March 1, 1999, have a dip tube that allows liquid to flow out of cylinder in upright position. Cylinders manufactured March 1, 1999 and later DO NOT have a dip tube and MUST be positioned upside down to allow liquid to flow.

SRecovery cylinder service pressure rating must be 400 psig. DOT 4BA400 or DOT BW400.

SPuron systems should be charged with liquid refrigerant. Use a commercial-type metering device in the manifold hose. S Manifold sets should be minimum 700 psig high side and 180 psig low side with 550 psig low side retard.

S Use hoses with minimum 700 psig service pressure rating.

S Leak detectors should be designed to detect HFC refrigerant. S Puron, as with other HFCs, is only compatible with POE oils. S Vacuum pumps will not remove moisture from oil.

S Only use factory-specified liquid-line filter driers with rated working pressures no less than 600 psig. S Do not install a suction-line filter drier in liquid line.

S POE oils absorb moisture rapidly. Do not expose oil to atmosphere. S POE oils may cause damage to certain plastics and roofing materials. S Wrap all filter driers and service valves with wet cloth when brazing. S A Puron liquid-line filter drier is required on every unit.

S Do not use an R-22 TXV.

S Never open system to atmosphere while it is under a vacuum.

S When system must be opened for service, break vacuum with dry nitrogen and replace filter driers. S Do not vent Puron into the atmosphere.

S Observe all warnings, cautions, and bold text.

S Do not leave Puron suction line driers in place for more than 72 hrs.

577D-- -- A

37

Image 37
Contents Table of Contents Installation InstructionsReceiving and Installation Safety ConsiderationsIntroduction Check EquipmentRig and Place Unit Provide ClearancesUNIT/STRUCTURAL Damage Hazard Unit Falling HazardCPRFCURB010A00 SizeCPRFCURB011A00 CPRFCURB012A00577D--A24-30 Unit Dimensions 577D--A36-60 Unit Dimensions Physical Data Unit 577D--A Indoor FAN Physical Data Con’t Unit 577D--ACabinet Model Rigging Weight Select and Install DuctworkPersonal Injury Hazard Supply and Return Duct Opening Provide for Condensate DisposalInstall Gas Piping Install Flue HoodCarbon Monoxide Poisoning Hazard Fire or Explosion Hazard Install Electrical ConnectionsUnit Component Damage Hazard Electronic Air Cleaner Outdoor Air Temperature Sensor OATMaximum Gas Flow Capacity Humidifier ConnectionsTypical Installation Control Plate PRE-START-UP Unit Start-Up and TroubleshootingSTART-UP FIRE, EXPLOSION, Electrical Shock and Environmental HazardFurnace Control Troubleshooting Indoor Fan Motor Troubleshooting577D a A10217L A10219C A10219L HP/AC Control Troubleshooting Unit Operation Hazard Sequence of OperationHeat Pump/Air Conditioner Board Status Codes Air Delivery and Temperature Rise at Rated Heating InputEvolution Controlled LOW Ambient Cooling Dehumidification ModeCheck GAS Input Natural GAS Unit Damage HazardU.S.A Fire and Unit Damage HazardAltitude Derate Multiplier for U.S.A CanadaCheck Burner Flame Check GAS Input Propane GASCheck for Refrigerant Leaks Start-Up AdjustmentsECM Wet Coil Pressure Drop IN. W.C Heating InputsFilter Pressure Drop Table IN. W.C Cooling Charging Table-Subcooling Maintenance Electrical Controls and Wiring Inducer Pressure SwitchOutdoor Coil, Indoor Coil, and Condensate Drain Pan Outdoor FanRefrigerant Circuit Pressure Switches Refrigerant CircuitIndoor Airflow Copeland Scroll Compressor Puron RefrigerantTroubleshooting Final Checks Care and Maintenance Observe all warnings, cautions, and bold text Symptom Cause Remedy Troubleshooting Chart CoolingBurners will not ignite Troubleshooting Chart Gas Furnace OperationTemperatures START-UP ChecklistPreliminary Information Model no III. START-UP Electrical Supply Voltage Compressor Amps

577D----A specifications

The Bryant 577D----A is a highly regarded model in the HVAC industry, representing a blend of efficiency, performance, and advanced technology. This heating and cooling unit is designed to cater to a variety of residential and light commercial applications, making it a versatile choice for consumers looking to enhance their indoor climate control systems.

One of the standout features of the Bryant 577D----A is its impressive energy efficiency rating. With a Seasonal Energy Efficiency Ratio (SEER) typically exceeding 14, this model is engineered to reduce energy consumption, helping homeowners lower their utility bills while minimizing environmental impact. The unit also employs a two-stage cooling system, which not only improves comfort by maintaining more consistent temperatures but also provides enhanced dehumidification during hotter months.

The technology used in the Bryant 577D----A is noteworthy. The unit incorporates a variable-speed compressor that adapts to the specific cooling or heating needs of the space, ensuring optimal performance at all times. This advanced feature not only contributes to energy savings but also allows for quieter operation compared to single-stage systems. The inclusion of a smart thermostat integration further enhances convenience, enabling users to manage their HVAC system remotely and optimize settings according to their schedules.

Additional characteristics of the Bryant 577D----A include a durable construction designed to withstand various environmental conditions. The cabinet is made from quality materials that protect against corrosion and other factors that could affect the unit's longevity. Furthermore, the unit operates quietly, thanks to sound-dampening technologies, which is a significant advantage for residential areas where noise can be a concern.

Maintenance is also simplified with the Bryant 577D----A, as it is equipped with self-diagnostics for easy troubleshooting. This feature alerts users to potential issues before they escalate, promoting efficient operation and prolonging the lifespan of the system.

In conclusion, the Bryant 577D----A stands out as a superior choice for those seeking reliability and efficiency in their HVAC solutions. With its energy-efficient operation, advanced technologies, and robust construction, it serves as a valuable investment for homeowners committed to comfort and sustainability.