Bryant manual Electrical Data Ð 580G,H240-360

Page 12

Table 3Ð Electrical Data Ð 580G,H240-360

UNIT

NOMINAL

VOLTAGE

COMPRESSOR

 

OFM

 

 

IFM

POWER

COMBUSTION

 

POWER SUPPLY

RANGE

No. 1

No. 2

 

 

 

EXHAUST

FAN MOTOR

 

SIZE

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

580G,H

(3 Ph 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

Qty

Hp

 

FLA

Hp

 

FLA

FLA

LRA

FLA

 

MCA

 

MOCP*

 

 

 

(ea)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

16.7/

Ð

Ð

0.96

 

101.8/100.3

 

125/125

 

 

 

 

 

 

 

 

 

 

 

 

 

15.2

23.6

41.6

0.96

 

125.4/123.9

 

150/150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230

187

254

39.1

228

25.6

160

2

1

 

5.3

10

 

30.8/

Ð

Ð

0.96

 

115.9/113.1

 

150/150

 

 

 

28.0

23.6

41.6

0.96

 

139.5/136.7

 

175/175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

46.2/

Ð

Ð

0.96

 

131.3/127.1

 

150/150

 

 

 

 

 

 

 

 

 

 

 

 

 

42.0

23.6

41.6

0.96

 

154.9/150.7

 

175/175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

7.6

Ð

Ð

0.50

 

49.4

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

62.0

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

460

414

508

19.9

114

11.5

80

2

1

 

2.7

10

 

14.0

Ð

Ð

0.50

 

55.8

 

70

 

 

12.6

23.6

0.50

 

68.4

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

21.0

Ð

Ð

0.50

 

62.8

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

75.4

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

6.1

Ð

Ð

0.50

 

40.5

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

53.1

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

518

632

16.0

91

9.6

64

2

1

 

2.4

10

 

11.0

Ð

Ð

0.50

 

45.4

 

60

 

 

 

12.6

23.6

0.50

 

58.0

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

17.0

Ð

Ð

0.50

 

51.4

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

64.0

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

24.2/

Ð

Ð

0.96

 

122.8/120.6

 

150/150

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0

23.6

41.6

0.96

 

146.4/144.2

 

175/175

 

208/230

187

254

39.1

228

39.1

228

2

1

 

5.3

10

 

30.8/

Ð

Ð

0.96

 

129.4/126.6

 

150/150

 

 

 

28.0

23.6

41.6

0.96

 

153.0/150.2

 

175/175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

46.2/

Ð

Ð

0.96

 

144.8/140.6

 

175/175

 

 

 

 

 

 

 

 

 

 

 

 

 

42.0

23.6

41.6

0.96

 

168.4/164.0

 

200/200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

11.0

Ð

Ð

0.50

 

61.2

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

73.8

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

460

414

508

19.9

114

19.9

114

2

1

 

2.7

10

 

14.0

Ð

Ð

0.50

 

64.2

 

80

 

 

12.6

23.6

0.50

 

76.8

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

21.0

Ð

Ð

0.50

 

71.2

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

83.8

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

9.0

Ð

Ð

0.50

 

49.8

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

62.4

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

518

632

16.0

91

16.0

91

2

1

 

2.4

10

 

11.0

Ð

Ð

0.50

 

51.8

 

60

 

 

 

12.6

23.6

0.50

 

64.4

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

17.0

Ð

Ð

0.50

 

57.8

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

70.4

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

FLA

Ð Full Load Amps

HACR

Ð Heating, Air Conditioning and Refrigeration

IFM

Ð Indoor (Evaporator) Fan Motor

LRA

Ð Locked Rotor Amps

MCA

Ð Minimum Circuit Amps

MOCP Ð Maximum Overcurrent Protection

NEC

Ð National Electrical Code

OFM

Ð Outdoor (Condenser) Fan Motor

RLA

Ð Rated Load Amps

*Fuse or HACR circuit breaker.

or

NOTES:

1.In compliance with NEC requirements for multimotor and combina- tion load equipment (refer to NEC Articles 430 and 440), the over- current protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker.

2.Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent voltage imbalance.

% Voltage Imbalance

= 100 x

max voltage deviation from average voltage

average voltage

 

EXAMPLE: Supply voltage is 460-3-60.

AB = 452 v

BC = 464 v

AC = 455 v

Average Voltage =

452 + 464 + 455

 

3

=

1371

 

3

=

457

Determine maximum deviation from average voltage. (AB) 457 − 45 2 = 5 v

(BC) 464 − 45 7 = 7 v

(AC) 457 − 45 5 = 2 v Maximum deviation is 7 v.

Determine percent voltage imbalance.

% Voltage Imbalance = 100 x

 

7

457

 

= 1.53%

 

 

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

Ð12Ð

Image 12
Contents Contents Safety ConsiderationsInstallation Provide Unit Support Roof CurbAlternate Unit Support II. RIG and Place UnitBase Unit Dimensions, 580G240-360 Unit Size Operating Corner WeightBase Unit Dimensions, 580H240-360 Must be in Place When Rigging Unit WeightSpecications Unit 580G,HIII. Field Fabricate Ductwork IV. Unit Duct ConnectionsFlue Hood VI. Trap Condensate DrainVII. GAS Piping Power Wiring Field Power SupplyVIII. Electrical Connections Controls OptionsSIO LEDField Control Wiring Electrical Data Ð 580G,H240-360 Ð13Ð IX. OUTDOOR-AIR Inlet Assembly EconomizerAdding Seal Strip to Mounting Flange Hood Sides Economizer Settings Mounting Angle With Tabs Attached to Filter Track AssemblyEnthalpy Control and Sensor Power EXHAUST/BAROMETRIC Relief Damper Hood Economizer DetailsXI. Accessories Motormaster III Control InstallationLow Ambient Kit Sensor Location PRE-START-UPDIP Switch Conguration DIP Switch Factory SettingsSTART-UP Cooling Section START-UP and Adjustments Checking Cooling Control OperationII. Heating Section START-UP and Adjustments Smoke Control Modes Smoke DetectorIndoor Air Quality Control Time Guard CircuitIV. Indoor Airflow and Airflow Adjustments Evaporator Fan Performance AdjustmentHead Pressure Control Motormaster III ControlCondenser-Fan Adjustment GAS Valve AdjustmentNatural Gas Fan Performance, 580G240-360 Ð Vertical Discharge Units AirflowAvailable External Static Pressure Airflow Fan Performance Ð Power Exhaust Motor LimitationsAir Quantity Limits VII. Power Exhaust Operation Care and MaintenanceVI. Main Burners VIII. Head Pressure ControlService CleaningII. Lubrication Spark Gap Adjustment III. Evaporator FAN Service and Replacement IV. EVAPORATOR-FAN Motor ReplacementPower Failure VI. Refrigerant ChargeXIII. Replacement Parts VII. Filter DrierVIII. Thermostatic Expansion Valve TXV IX. Protective DevicesTroubleshooting Control Board LED Alarms II. Error Code SummaryIGC Board Error Code Summary LED Error Description Troubleshooting Blinks Code CommentsI/O Channel Designations Base Module Terminal AssignmentSAT IGC Control Heating and Cooling AHA IDMIFC IfcbTable a Table BPower Schematic 580G,H240-360 Ð 24 V Control Schematic 580G,H240-360 Component Arrangement 580G,H240-360 Packaged Service Training START-UP Checklist TemperaturesSTART-UP Electrical PressuresGeneral

580G specifications

The Bryant 580G is a high-efficiency gas furnace designed to deliver optimal heating performance while maximizing energy savings. This model stands out in the Bryant product lineup due to its advanced features and robust technology, making it a popular choice for homeowners seeking reliable comfort in colder climates.

One of the key characteristics of the Bryant 580G is its efficiency rating. With an annual fuel utilization efficiency (AFUE) of up to 92.1%, this furnace ensures that a substantial portion of the fuel consumed is converted into heat, minimizing energy waste and reducing utility bills. This high-efficiency performance is particularly beneficial for those looking to lower their environmental footprint and operate a more sustainable home heating system.

The 580G uses a two-stage heating process, which allows it to operate at two levels of output. During mild weather, the furnace can run on a lower setting, providing gentle warmth while conserving energy. When temperatures drop, the system automatically ramps up to a higher output to maintain comfort. This feature not only enhances energy efficiency but also helps to eliminate temperature fluctuations, ensuring consistent warmth throughout the home.

Noise reduction technology is another remarkable aspect of the Bryant 580G. Equipped with a variable speed blower motor, this furnace operates quietly, providing a more peaceful indoor environment. The motor allows for customizable airflow, which further aids in maintaining an even temperature across different rooms and spaces.

The furnace is built with high-quality materials and features a compact design, making it a suitable option for various installation locations. Additionally, it is compatible with Bryant’s EcoNet Smart Home Management System, which enables homeowners to monitor and control their heating system remotely via a smartphone app. This integration enhances convenience and allows for timely adjustments to heating schedules, promoting energy savings.

Safety is a priority with the 580G. It features an integrated safety switch and a reliable flame sensor to ensure safe operation. With its durable construction and thoughtful engineering, the Bryant 580G is designed to withstand the demands of everyday use while providing peace of mind to homeowners.

In summary, the Bryant 580G gas furnace combines high efficiency, advanced technology, and user-friendly features. Its ability to operate quietly, adapt to temperature changes, and integrate with smart home technology makes it a leading choice for efficient home heating solutions. This furnace not only provides comfort but also offers long-term energy savings, making it a smart investment for any household.