Bryant 580G manual IGC Control Heating and Cooling

Page 36

LEGEND

IDM Ð Induced-Draft Motor

IGC Ð Integrated Gas Controller

NOTE: Thermostat Fan Switch in the ``AUTO'' position.

Fig. 45 Ð IGC Control (Heating and Cooling)

Ð36Ð

Image 36
Contents Contents Safety ConsiderationsInstallation Provide Unit Support Roof CurbAlternate Unit Support II. RIG and Place UnitBase Unit Dimensions, 580G240-360 Unit Size Operating Corner WeightBase Unit Dimensions, 580H240-360 Must be in Place When Rigging Unit WeightSpecications Unit 580G,HIII. Field Fabricate Ductwork IV. Unit Duct ConnectionsFlue Hood VI. Trap Condensate DrainVII. GAS Piping Power Wiring Field Power SupplyVIII. Electrical Connections Controls OptionsSIO LEDField Control Wiring Electrical Data Ð 580G,H240-360 Ð13Ð IX. OUTDOOR-AIR Inlet Assembly EconomizerAdding Seal Strip to Mounting Flange Hood Sides Economizer Settings Mounting Angle With Tabs Attached to Filter Track AssemblyEnthalpy Control and Sensor Power EXHAUST/BAROMETRIC Relief Damper Hood Economizer DetailsXI. Accessories Motormaster III Control InstallationLow Ambient Kit Sensor Location PRE-START-UPDIP Switch Conguration DIP Switch Factory SettingsSTART-UP Cooling Section START-UP and Adjustments Checking Cooling Control OperationII. Heating Section START-UP and Adjustments Smoke Control Modes Smoke DetectorIndoor Air Quality Control Time Guard CircuitIV. Indoor Airflow and Airflow Adjustments Evaporator Fan Performance AdjustmentHead Pressure Control Motormaster III ControlCondenser-Fan Adjustment GAS Valve AdjustmentNatural Gas Fan Performance, 580G240-360 Ð Vertical Discharge Units AirflowAvailable External Static Pressure Airflow Fan Performance Ð Power Exhaust Motor LimitationsAir Quantity Limits VII. Power Exhaust Operation Care and MaintenanceVI. Main Burners VIII. Head Pressure ControlService CleaningII. Lubrication Spark Gap Adjustment III. Evaporator FAN Service and Replacement IV. EVAPORATOR-FAN Motor ReplacementPower Failure VI. Refrigerant ChargeXIII. Replacement Parts VII. Filter DrierVIII. Thermostatic Expansion Valve TXV IX. Protective DevicesTroubleshooting Control Board LED Alarms II. Error Code SummaryIGC Board Error Code Summary LED Error Description Troubleshooting Blinks Code CommentsI/O Channel Designations Base Module Terminal AssignmentSAT IGC Control Heating and Cooling AHA IDMIFC IfcbTable a Table BPower Schematic 580G,H240-360 Ð 24 V Control Schematic 580G,H240-360 Component Arrangement 580G,H240-360 Packaged Service Training START-UP Checklist TemperaturesSTART-UP Electrical PressuresGeneral

580G specifications

The Bryant 580G is a high-efficiency gas furnace designed to deliver optimal heating performance while maximizing energy savings. This model stands out in the Bryant product lineup due to its advanced features and robust technology, making it a popular choice for homeowners seeking reliable comfort in colder climates.

One of the key characteristics of the Bryant 580G is its efficiency rating. With an annual fuel utilization efficiency (AFUE) of up to 92.1%, this furnace ensures that a substantial portion of the fuel consumed is converted into heat, minimizing energy waste and reducing utility bills. This high-efficiency performance is particularly beneficial for those looking to lower their environmental footprint and operate a more sustainable home heating system.

The 580G uses a two-stage heating process, which allows it to operate at two levels of output. During mild weather, the furnace can run on a lower setting, providing gentle warmth while conserving energy. When temperatures drop, the system automatically ramps up to a higher output to maintain comfort. This feature not only enhances energy efficiency but also helps to eliminate temperature fluctuations, ensuring consistent warmth throughout the home.

Noise reduction technology is another remarkable aspect of the Bryant 580G. Equipped with a variable speed blower motor, this furnace operates quietly, providing a more peaceful indoor environment. The motor allows for customizable airflow, which further aids in maintaining an even temperature across different rooms and spaces.

The furnace is built with high-quality materials and features a compact design, making it a suitable option for various installation locations. Additionally, it is compatible with Bryant’s EcoNet Smart Home Management System, which enables homeowners to monitor and control their heating system remotely via a smartphone app. This integration enhances convenience and allows for timely adjustments to heating schedules, promoting energy savings.

Safety is a priority with the 580G. It features an integrated safety switch and a reliable flame sensor to ensure safe operation. With its durable construction and thoughtful engineering, the Bryant 580G is designed to withstand the demands of everyday use while providing peace of mind to homeowners.

In summary, the Bryant 580G gas furnace combines high efficiency, advanced technology, and user-friendly features. Its ability to operate quietly, adapt to temperature changes, and integrate with smart home technology makes it a leading choice for efficient home heating solutions. This furnace not only provides comfort but also offers long-term energy savings, making it a smart investment for any household.