Before Each Start-Up:

1.Place On/Auto/Off lever to "Off".

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Attach hose and accessories.

NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s

maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place.

The compressor is ready for use.

MAINTENANCE

Customer Responsibilities

Before

Daily

each

or after

each

use

use

 

Every

100Yearly

hours

Check Safety Valve

 

 

Drain Tank

 

 

Air Filter

1

 

 

 

Air compressor pump intake

 

and exhaust valves

 

 

 

 

1- more frequent in dusty or humid conditions

 

 

 

 

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit

unplug or disconnect electrical supply to the air compressor, bleed tank of

pressure, and allow the air compressor to cool.

To ensure efficient operation and longer life of the air compressor, a routine

maintenance schedule should be prepared and followed. The above routine

maintenance schedule is geared to an air compressor in a normal working

environment operating on a daily basis. If necessary, the schedule should

be modified to suit the conditions under which your air compressor is used.

The modifications will depend upon the hours of operation and the working

environment. Compressors in an extremely dirty and/or hostile environment will

require a greater frequency of all maintenance checks.

13- ENG

A10244

Image 13
Contents C6110 ModelImportant Safety Instructions Safety Guidelines DefinitionsOr serious injury Or moderate injury Death or serious injuryAlways remain in attendance with What Could HappenAttachments & Accessories Electricity. Like any other electrically Safety equipment must be properlyRepairs attempted by unqualified Personnel can result in serious injuryHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesAccessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air Compressor Voltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationHow to Stop How to Use Your UnitHow to Start MaintenanceBefore Each Start-Up Customer ResponsibilitiesAir Filter Inspection and Replacement To Check Safety ValveTo Drain Tank Air Compressor Pump Intake and Exhaust ValvesTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10244 Limited Warranty