PYLE Audio C6110 instruction manual To Replace Regulator

Page 16

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.

4.Using an adjustable wrench remove pressure relief tube.

Outlet

Pressure

Gauge

Quick

Connect

Regulator

Pressure

Relief

Tube

5.Remove the regulator.

6.Apply pipe sealant tape to the nipple on the standpipe.

7.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Nipple

Regulator

Regulator

Arrow

8.Reapply pipe sealant to outlet pressure gauge and quick connect.

9.Reassemble outlet pressure gauge, pressure relief tube and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

A10244

16- ENG

Image 16
Contents Model C6110Safety Guidelines Definitions Important Safety InstructionsOr serious injury Or moderate injury Death or serious injuryWhat Could Happen Always remain in attendance withAttachments & Accessories Safety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Equip area of operation with a fire extinguisherSpecifications AccessoriesGlossary Duty CycleAssembly InstallationUnpacking Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationHow to Use Your Unit How to Stop Maintenance How to Start Before Each Start-Up Customer ResponsibilitiesTo Check Safety Valve Air Filter Inspection and ReplacementTo Drain Tank Air Compressor Pump Intake and Exhaust ValvesService and Adjustments To Replace or Clean Check ValveTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10244 Limited Warranty