PYLE Audio C6110 instruction manual Service and Adjustments, To Replace or Clean Check Valve

Page 15

SERVICE AND ADJUSTMENTS

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube up away from check valve.

4.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve.

5.Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly.

Outlet Tube

Nut

 

Pressure

 

Relief

 

Tube

 

 

Check

 

Valve

 

Nut

6.Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position, if not the check valve needs to be cleaned or replaced.

7.Clean or replace the check valve. A solvent, such as paint or varnish remover can be used to clean the check valve.

Screwdriver

In open position nothing is visible.

In closed position disc is visible.

8.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

9.Replace the pressure release tube. Tighten nuts.

10.Replace the outlet tube and tighten nuts.

11.Replace shrouds.

12.Perform the Break-in Procedure. See "Break-in Procedure" in the "Operation" section.

15- ENG

A10244

Image 15
Contents C6110 ModelDeath or serious injury Safety Guidelines DefinitionsImportant Safety Instructions Or serious injury Or moderate injuryAlways remain in attendance with What Could HappenAttachments & Accessories Personnel can result in serious injury Safety equipment must be properlyElectricity. Like any other electrically Repairs attempted by unqualifiedHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesDuty Cycle SpecificationsAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationHow to Stop How to Use Your UnitCustomer Responsibilities MaintenanceHow to Start Before Each Start-UpAir Compressor Pump Intake and Exhaust Valves To Check Safety ValveAir Filter Inspection and Replacement To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10244 Limited Warranty