PROBLEM

CAUSE

CORRECTION

Pressure reading

It is normal for "some"

If there is an excessive

on the regulated

pressure drop to occur.

amount of pressure drop

pressure gauge

 

when the accessory is used,

drops when an

 

adjust the regulator following

accessory is

 

the instructions in the

used.

 

"Description of Operation"

 

 

paragraph in the "Operation"

 

 

section.

 

 

NOTE: Adjust the regulated

 

 

pressure under flow

 

 

conditions (while accessory is

 

 

being used).

Knocking Noise.

Possible defect in safety

Operate safety valve

 

valve.

manually by pulling on ring.

 

 

If valve still leaks, it should

 

 

be replaced.

 

Defective check valve.

Remove and clean, or

 

 

replace.

 

 

 

Compressor is

Prolonged excessive use of

Decrease amount of air

not supplying

air.

usage.

enough air

Compressor is not large

Check the accessory

to operate

accessories.

enough for air requirement.

air requirement. If it is

 

 

higher than the SCFM or

 

 

pressure supplied by your

 

 

air compressor, you need a

 

 

larger compressor.

 

Hole in hose.

Check and replace if

 

 

required.

 

Check valve restricted.

Remove and clean, or

 

 

replace.

 

Air leaks.

Tighten fittings.

 

Restricted air intake filter.

Clean or replace air intake

 

 

filter. Do not operate the

 

 

air compressor with the

 

 

filter removed. Refer to the

 

 

"Air Filter" paragraph in the

 

 

"Maintenance" section.

Regulator knob

Damaged regulator.

Replace.

has continuous

 

 

air leak.

 

 

 

 

 

19- ENG

A10244

Image 19
Contents C6110 ModelDeath or serious injury Safety Guidelines DefinitionsImportant Safety Instructions Or serious injury Or moderate injuryAlways remain in attendance with What Could HappenAttachments & Accessories Personnel can result in serious injury Safety equipment must be properlyElectricity. Like any other electrically Repairs attempted by unqualifiedHazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesDuty Cycle SpecificationsAccessories GlossaryLocation of the Air Compressor AssemblyInstallation UnpackingVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationHow to Stop How to Use Your UnitCustomer Responsibilities MaintenanceHow to Start Before Each Start-UpAir Compressor Pump Intake and Exhaust Valves To Check Safety ValveAir Filter Inspection and Replacement To Drain TankTo Replace or Clean Check Valve Service and Adjustments To Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10244 Limited Warranty