PYLE Audio C6110 Assembly, Installation, Unpacking, Location of the Air Compressor

Page 9
Plug
Grounding Pin

ASSEMBLY

Unpacking

1.Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other contain- ers on or near these openings.

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an

escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accor- dance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

Grounded Outlets

4. If these grounding instructions are not completely understood, or if in

doubt as to whether the compressor is properly grounded, have the instal- lation checked by a qualified electrician.

Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

9- ENG

A10244

Image 9
Contents C6110 ModelImportant Safety Instructions Safety Guidelines DefinitionsOr serious injury Or moderate injury Death or serious injuryAlways remain in attendance with What Could HappenAttachments & Accessories Electricity. Like any other electrically Safety equipment must be properlyRepairs attempted by unqualified Personnel can result in serious injury Hazard Warning Risk from Moving Parts Result in serious burns How To Prevent ItEquip area of operation with a fire extinguisher Keep children away from the air compressor at all timesAccessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air CompressorVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationHow to Stop How to Use Your UnitHow to Start MaintenanceBefore Each Start-Up Customer ResponsibilitiesAir Filter Inspection and Replacement To Check Safety ValveTo Drain Tank Air Compressor Pump Intake and Exhaust ValvesTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Troubleshooting Being used Check wiring connection ENG A10244 Limited Warranty