Bryant 502A FIELD-INSTALLED Accessories, 88EN Electric Heat Module, Head Pressure Control Damper

Page 4

FIELD-INSTALLED ACCESSORIES

Thermostat and Subbase — Attractive wall-mounted 24-v accessory provides precise temperature control. Automatic and Manual changeover models available. A thermostat subbase is available that works with Cycle-LOC™ circuitry. If a safety device trips, compressor locks out and subbase warning light (LK OUT) alerts occupant.

Two models available: Two stage cool/two stage heat and one stage cool/one stage heat.

Time Guard® II Circuit (standard on single-phase units) — Time Guard II device prevents short cycling of compressor if thermostat is rapidly changed; automatically prevents compres- sor from restarting for 5 minutes after shutdown.

Electric Heaters — A wide range of models available from 5 to

30kW, 208-, 240- and 480-v, single- and 3-ph units. Mount eas- ily on 502A discharge opening. Heater control box accessible from the bottom of heater.

Condensate Pump — The condensate pump is used when the distance and slope to the nearest drain is far enough to prevent the natural drainage of unit. The pump is mounted remotely from the unit and includes a signal light (field-installed) which illuminates when the reservoir rises beyond a certain level. The unit automatically shuts down when this reservoir level is achieved.

Head Pressure Control Damper — This accessory is duct mounted and allows unit to mechanically cool down to 0° F.

Damper dimensions fit 024, 036 sizes.

NOTE: For use with 048 and 060 size units, ductwork from unit to damper must be reduced in size to fit damper dimensions.

Vibration Isolators — Package of four isolators used for damp- ening any unit vibration so that vibrating sounds are not transmitted to building structure. Isolators are spring, ceiling type.

 

88EN ELECTRIC HEAT MODULE

HEAD PRESSURE CONTROL DAMPER (in.)

 

 

 

 

ACCESSORY

 

 

 

 

 

 

DIMENSIONS (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

A

 

B

 

C

 

D

DUCT

 

 

502A

 

 

 

OPENING

 

 

 

 

 

 

 

 

 

 

 

024,036

131/

2

16

 

21/

2

81/

71/

8

x 14

 

 

 

 

 

 

 

2

 

 

 

 

048,060

24

 

213/

4

3

 

19

71/

x 207/

 

 

 

 

 

 

 

 

 

8

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Image 4
Contents FEATURES/BENEFITS Model 502AModel Number Nomenclature Table of ContentsARI* Capacity Ratings Operating Weight Distribution Center of Gravity DimensionsPhysical Data Unit 502AFIELD-INSTALLED Accessories AccessoryDimensions 88EN Electric Heat ModuleDimensions ft-in Base Unit DimensionsUnit Component Locations Selection Procedure with example Performance DataGross Cooling Capacities Performance DataEvaporator FAN Performance Belt Drive Evaporator FAN Performance Condenser FAN PerformanceControls Electrical DataOperating Sequence CoolingElectrical Data Typical Wiring SchematicsElectric Heater Static Pressure Drop in. wg Typical Wiring Schematics 502A024, 230-1-60 Units502A048,060, 230-1-60 Units 502A048,060, 575-3-60 Units BKR W/ATTypical Piping and Wiring OUTDOOR-AIR Temperature Operating Limits FApplication Data With Head Pressure Control Minimum MaximumGuide Specifications Indoor Packaged UnitPart 1 General Part 2 ProductsGuide Specifications Specifications Subject to Change Without Notice