Grizzly G1023S110 instruction manual Miter Gauge, To adjust the miter gauge

Page 27

Miter Gauge

The miter gauge for the Model G1023S Series has two setscrews in the miter bar which can be set to remove any loose movement between the miter bar and the T-slot.

To adjust the miter gauge:

1.Loosen or tighten the two miter bar setscrews (Figure 23) until the miter gauge slides freely in the slot, but has no loose movement.

2.Loosen the lock knob on the miter gauge and place a square against the face of the miter body and the miter bar.

3.Adjust the miter body until there is no space between the square and the miter bar.

4.Tighten the lock knob.

5.With the stop link (Figure 23) in the up posi- tion, loosen the jam nut and adjust the stop screw until it is seated against the stop link.

6.Loosen the setscrew on the left front side of the miter bar, adjust the pointer to 90û and retighten the setscrew.

7.To adjust to 45û, follow Steps 1-6while using an adjustable square.

8.After rotating the miter body from 45û to 90û and back a few times, double check your adjustments at both angles to ensure that you have accurately set your miter gauge.

Setscrew

Stop Link

Stop Screw

Jam Nut

Figure 23. Miter gauge adjustment points.

G1023S Series Heavy-Duty 10'' Table Saw

-25-

Image 27
Contents Model G1023S & G1023S110 HEAVY-DUTY Table SAWPage Table of Contents Safety Instructions For Power Tools Safety25ft 50ft 100ft Length AMP RatingAdditional Safety Instructions For Table Saws Following can help minimize kickbacks Avoiding Kickback Safety AccessoriesZero Clearance Table Inserts Push PaddlesFeatherboards Commentary Introduction110V Operation 220V Operation Circuit RequirementsModel G1023S Only Grounding Extension Cord Terms & Definitions Machine FeaturesMain Features Unpacking Piece Inventory SET UPG1023S Series component layout Bolt Hardware Recognition ChartWorking Clearance Clean UpSite Considerations Floor LoadBeginning Assembly Extension Wings Fence & Rails SwitchTo mount the switch Disconnect the machine from the power sourceMotor brace Cleanout Door Motor BraceGuard Bracket To install the blade guard assemblyTable Insert HandwheelBlade Guard/Splitter Saw BladeFront Support Blade Adjustment Bolt Miter Gauge To adjust the miter gaugeRecommended adjustment checklist Start Up RecommendedStarting the machine Blade Selection OperationsPage Crosscutting Typical ripping operation RippingSingle-blade dado cut Dado CuttingIf the cut is satisfactory, repeat with your fin- ish stock Rabbet cutting G1023S Series Heavy-Duty 10 Table Saw Rabbet CuttingRabbet cutting General MaintenanceLubricationTable BeltLubricate the areas indicated below every 12 months Belt deflection Date Approximate Hours Of Use Maintenance Performed 45˚ & 90˚ Stops Service AdjustmentsBlade Parallelism Page Trunnion mounting bolts Blade AlignmentPage G1023S Series Heavy-Duty 10 Table Saw G1023S Series Heavy-Duty 10 Table Saw Closure Motor Overall DimensionsCapacities ConstructionPage Cabinet Complete Miter Gauge Symptom Possible Cause Corrective Action Troubleshooting GuideG1023S Series Heavy-Duty 10 Table Saw G1023S Series Heavy-Duty 10 Table Saw Warranty and Returns Warranty Card BOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCCall Today For a Free Full Color Catalog