Bard W30H1, W24H1, W18H1, W48H1, W36H1, W42H1 Vent & Control Options, W18, W24 W30, W36 W42, W48, W60

Page 27

TABLE 11

VENT & CONTROL OPTIONS

Part Number

Description

W18, W24

W30, W36

W42, W48, W60

CMC-14

ODT

 

X

X

X

 

 

 

 

 

 

CMC-15

Start Kit (230V 1-Phase only)

1

X

X

X

 

 

 

 

 

 

SK111

Start Kit (230V 1-Phase only)

2

X

X

X

 

 

 

 

 

 

CMC-28

LAC

 

X

X

X

 

 

 

 

 

BFAD-2

Barometric Fresh Air Damper - Standard

X

 

 

 

 

 

 

 

 

BOP-2

Blank Off Plate

 

X

 

 

 

 

 

 

 

 

MFAD-2

Motorized Fresh Air Damper

 

X

 

 

 

 

 

 

 

CRV-2

Commercial Ventilator - Spring Return

X

 

 

 

 

 

 

 

 

EIFM-2B

Economizer

 

X

 

 

 

 

 

 

 

ERVF-A2

Energy Recovery Ventilator - 230 Volt

X

 

 

 

 

 

 

 

BFAD-3

Barometric Fresh Air Damper - Standard

 

X

 

 

 

 

 

 

 

BOP-3

Blank Off Plate

 

 

X

 

 

 

 

 

 

 

MFAD-3

Motorized Fresh Air Damper

 

 

X

 

 

 

 

 

 

CRVS-3

Commercial Ventilator - Spring Return

 

X

 

 

 

 

 

 

CRVP-3

Commercial Ventilator - Power Return

 

X

 

 

 

 

 

 

 

EIFM-3C

Economizer

 

 

X

 

 

 

 

 

 

ERVF-A3

Energy Recovery Ventilator - 230 Volt

 

X

 

 

 

 

 

 

ERVF-C3

Energy Recovery Ventilator - 460 Volt

 

X

 

 

 

 

 

 

BFAD-5

Barometric Fresh Air Damper - Standard

 

 

X

 

 

 

 

 

 

BOP-5

Blank Off Plate

 

 

 

X

 

 

 

 

 

 

MFAD-5

Motorized Fresh Air Damper

 

 

 

X

 

 

 

 

 

CRVS-5

Commercial Ventilator - Spring Return

 

 

X

 

 

 

 

 

CRVP-5

Commercial Ventilator - Power Return

 

 

X

 

 

 

 

 

 

EIFM-5C

Economizer

 

 

 

X

 

 

 

 

 

ERVF-A5

Energy Recovery Ventilator - 230 Volt

 

 

X

 

 

 

 

 

ERVF-C5

Energy Recovery Ventilator - 460 Volt

 

 

X

 

 

 

 

 

 

1PTCR Start Kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if SK111 is used.

2Start Capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Do not use if CMC-15 is used.

Manual

2100-511

Page

27 of 27

Image 27
Contents W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsShipping Damage GeneralHeat Pump Wall Mount Model Nomenclature Condensate Drain Duct WorkFilters Fresh AIR IntakeMounting the Unit Wall Mounting InformationSupply Return Right UnitW18H1, W24H1 Mountinginstructions W30H1, W36H1 Mountinginstructions W42H1, W48H1, W60H1 Mountinginstructions W30H1, W36H1, W42H1, W48H1, W60H1 Electric Heat ClearanceWall Mounting Instructions Common Wall Mounting Installations Wiring Main Power Wiring LOW Voltage WiringTAP Range Topping OFF System Charge Safety PracticesPhase Monitor Important Installer NoteHigh & LOW Pressure Switch Three Phase Scroll Compressor Start UP InformationPressure Service Ports Sequence of OperationDefrost Cycle Defrost Control Board Troubleshooting Solid State Heat Pump Control TroubleshootingprocedureTemperature F VS. Resistance R of Temperature Sensor Checking Temperature Sensor Outside Unit CircuitFAN Blade Setting Dimensions Removal of FAN ShroudRefrigerant Charge Cooling Pressure Table Heating Pressures ALL Temperatures FElectrical Specifications W**H Series Indoor Blower Performance RecommendedairflowElectric Heat Tables Maximum ESP of Operation Electric Heat onlyHeater Kits Circuit Breaker Wmcb & Pull Disconnect Wmpd Optional AccessoriesW18, W24 W30, W36 W42, W48, W60 Vent & Control Options