Bard W48H1, W24H1, W18H1, W36H1, W42H1, W60H1, W30H1 Electrical Specifications W**H Series

Page 23

TABLE 5

Electrical Specifications — W**H Series

 

 

 

 

Single Circuit

 

 

 

 

Dual Circuit

 

 

 

 

Rated

No. Field

4 Minimum

1 Maximum

2 Field

 

4 Minimum

1 Maximum

2 Field

2 Ground

 

2 Ground

Circuit

External Fuse

Power

Model

Volts

Power

Circuit

External Fuse

Power

Wire Size

Wire

Ampacity

or Ckt. Breaker

Wire Size

 

and Phase

Circuits

Ampacity

or Ckt. Brkr.

Wire Size

 

Ckt. A

Ckt. B

Ckt. A

Ckt. B

Ckt. A

Ckt. B

Ckt. A

Ckt. B

 

 

 

 

 

 

 

W18H1- A00, A0Z

 

1

16

20

12

12

 

 

 

 

 

 

 

 

A04

230/208-1

1

37

40

8

10

 

 

 

 

 

 

 

 

3 A08

 

1

58

60

6

10

 

 

 

 

 

 

 

 

W24H1- A00, A0Z

 

1

24

25

10

10

 

 

 

 

 

 

 

 

A04

230/208-1

1

44

50

8

10

 

 

 

 

 

 

 

 

3 A08

 

1

65

70

6

8

44

21

45

25

8

10

10

10

W24H1- B00, B0Z

230/208-3

1

17

20

12

12

 

 

 

 

 

 

 

 

B06

1

35

40

8

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W24H1- C00, C0Z

460-3

1

11

15

14

14

 

 

 

 

 

 

 

 

C06

1

21

25

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W30H1- A00, A0Z*

 

1

24

35

8

10

 

 

 

 

 

 

 

 

A05*

230/208-1

1

50

50

8

10

 

 

 

 

 

 

 

 

3 A10*

 

1 or 2

76

80

4

8

50

26

50

30

8

10

10

10

W30H1- B00, B0Z*

 

1

18

25

10

10

 

 

 

 

 

 

 

 

B06

230/208-3

1

36

40

8

10

 

 

 

 

 

 

 

 

3 B09*

 

1

45

45

8

10

 

 

 

 

 

 

 

 

W30H1- C00, C0Z*

 

1

11

15

14

14

 

 

 

 

 

 

 

 

C06

460-3

1

20

20

12

12

 

 

 

 

 

 

 

 

3 C09*

1

25

25

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C15

 

1

26

30

10

10

 

 

 

 

 

 

 

 

W36H1- A00, A0Z*

 

1

29

40

8

10

 

 

 

 

 

 

 

 

A05

230/208-1

1

55

60

6

10

 

 

 

 

 

 

 

 

3 A10*

1 or 2

81

90

4

8

55

26

60

30

6

10

10

10

 

5 A15

 

1 or 2

84

90

4

8

55

52

60

60

6

6

10

10

W36H1- B00, B0Z*

 

1

23

30

10

10

 

 

 

 

 

 

 

 

B06

230/208-3

1

41

45

8

10

 

 

 

 

 

 

 

 

3 B09*

1

50

50

8

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 B15

 

1

51

60

8

10

 

 

 

 

 

 

 

 

W36H1- C00, C0Z*

 

1

12

15

14

14

 

 

 

 

 

 

 

 

C06

460-3

1

21

25

10

10

 

 

 

 

 

 

 

 

3 C09*

1

25

25

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C15

 

1

26

30

10

10

 

 

 

 

 

 

 

 

W42H1- A00, A0Z

 

1

36

50

8

10

 

 

 

 

 

 

 

 

A05

230/208-1

1

62

70

6

8

36

26

50

30

8

10

10

10

3 A10

1 or 2

88

90

3

8

36

52

50

60

8

6

10

10

 

5 A15

 

1 or 2

88

90

3

8

36

52

50

60

8

6

10

10

W42H1- B00, B0Z

 

1

26

35

8

10

 

 

 

 

 

 

 

 

B06

230/208-3

1

44

50

8

10

 

 

 

 

 

 

 

 

3 B09

1

53

60

6

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 B15

 

1

53

60

6

10

 

 

 

 

 

 

 

 

W42H1- C00, C0Z

 

1

13

15

14

14

 

 

 

 

 

 

 

 

C06

460-3

1

22

25

10

10

 

 

 

 

 

 

 

 

3 C09

1

26

30

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 C15

 

1

26

30

10

10

 

 

 

 

 

 

 

 

W48H1- A00, A0Z

 

1

37

50

8

10

 

 

 

 

 

 

 

 

A04

 

1

58

60

6

10

 

 

 

 

 

 

 

 

A05

230/208-1

1 or 2

63

70

6

8

37

26

50

30

8

10

10

10

3 A10

1 or 2

89

90

3

8

37

52

50

60

8

6

10

10

 

5 A15

 

1 or 2

89

90

3

8

37

52

50

60

8

6

10

10

5 A20

 

1 or 2

111

125

2

6

59

52

60

60

6

6

10

10

W48H1- B00, B0Z

 

1

29

35

8

10

 

 

 

 

 

 

 

 

B06

 

1

47

50

8

10

 

 

 

 

 

 

 

 

3 B09

230/208-3

1

56

60

6

10

 

 

 

 

 

 

 

 

5 B15

 

1

56

60

6

10

 

 

 

 

 

 

 

 

5 B18

 

1 or 2

62

70

6

8

34

28

40

30

8

10

10

10

W48H1- C00, C0Z

 

1

14

20

12

12

 

 

 

 

 

 

 

 

3 C09

460-3

1

27

30

10

10

 

 

 

 

 

 

 

 

5 C15

 

1

27

30

10

10

 

 

 

 

 

 

 

 

W60H1- A00, A0Z

 

1

41

60

8

10

 

 

 

 

 

 

 

 

A05

 

1 or 2

67

80

4

8

41

26

60

30

8

10

10

10

3 A10

230/208-1

1 or 2

93

100

3

8

41

52

60

60

8

6

10

10

5 A15

 

1 or 2

93

100

3

8

41

52

60

60

8

6

10

10

5 A20

 

1 or 2

111

125

2

6

59

52

60

60

6

6

10

10

W60H1- B00, B0Z

 

1

28

40

8

10

 

 

 

 

 

 

 

 

3 B09

230/208-3

1

55

60

6

10

 

 

 

 

 

 

 

 

5 B15

1

55

60

6

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 B18

 

1

62

70

6

10

34

28

40

30

8

10

10

10

W60H1- C00, C0Z

 

1

16

20

12

12

 

 

 

 

 

 

 

 

3 C09

460-3

1

28

30

10

10

 

 

 

 

 

 

 

 

5 C15

 

1

28

30

10

10

 

 

 

 

 

 

 

 

1Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.

2 Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes.

3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing.

Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.

* Top outlet supply option is available only factory installed and only on the selected models.

IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes.

Manual

2100-511

Page

23 of 27

Image 23
Contents W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsHeat Pump Wall Mount Model Nomenclature Shipping DamageGeneral Condensate Drain Duct WorkFilters Fresh AIR IntakeMounting the Unit Wall Mounting InformationSupply Return Right UnitW18H1, W24H1 Mountinginstructions W30H1, W36H1 Mountinginstructions W42H1, W48H1, W60H1 Mountinginstructions W30H1, W36H1, W42H1, W48H1, W60H1 Electric Heat ClearanceWall Mounting Instructions Common Wall Mounting Installations TAP Range Wiring Main PowerWiring LOW Voltage Wiring Topping OFF System Charge Safety PracticesPhase Monitor Important Installer NoteHigh & LOW Pressure Switch Three Phase Scroll Compressor Start UP InformationDefrost Cycle Pressure Service PortsSequence of Operation Defrost Control Board Troubleshooting Solid State Heat Pump Control Troubleshootingprocedure Temperature F VS. Resistance R of Temperature Sensor Checking Temperature Sensor Outside Unit CircuitRefrigerant Charge FAN Blade Setting DimensionsRemoval of FAN Shroud Cooling Pressure Table Heating Pressures ALL Temperatures FElectrical Specifications W**H Series Indoor Blower Performance RecommendedairflowElectric Heat Tables Maximum ESP of Operation Electric Heat onlyHeater Kits Circuit Breaker Wmcb & Pull Disconnect Wmpd Optional AccessoriesW18, W24 W30, W36 W42, W48, W60 Vent & Control Options