Impulse IM200 F18 manual Inserting Fuel Cell

Page 12

Fuel Cell and Metering Valve

Inserting Fuel Cell

Inserting the metering valve/fuel cell assembly into the TrimMaster 18Finish Nailer is very simple. To begin, press up at the bottom of the actuator cover and pivot outward to open. The cover will swing out of the way.

2. PULL OUT

1. PRESS UP

P

Next, with the metering valve stem pointed toward the front of the tool, insert the metering valve/fuel cell assembly.

P

As you slide the metering valve/fuel cell assembly into the TrimMaster 18Finish Nailer, you will notice a yellow adapter at the top of the cylinder pocket. As shown in the illustration, this adapter is designed to ensure that the metering valve stem is properly aligned with the small hole, or orifice, that leads to the combustion chamber. Insert the metering valve stem into the orifice of the yellow-colored adapter.

Yellow

Fuel Cell

Adapter

 

Yellow Metering

Valve

Metering Valve Stem

Close the actuator cover to complete the loading of fuel in the TrimMaster 18 Finish Nailer. Do this by swinging it up and over the fuel valve/cylinder assembly, and pushing down until the actuator cover snaps into position.

2. PUSH DOWN

 

1. SWING BACK

 

P

11

Image 12
Contents Operating Manual Contents Introduction and Warranty TrimMaster 18 Finish Nailer Operating ManualFor the nearest Paslode representative call 1-800 Specifications Dimensions Weight-with batteryAn Overview of the Cordless TrimMaster 18 Finish Nailer DescriptionSafety Instructions Never Assume the Tool is Empty Or SQUEEZING, the TriggerDo not Load Fasteners with the Trigger AND/OR Work Contacting Element PressedKeep the Tool Clean Battery DisposalNever Drive Fasteners Into Areas with Concealed Hazards Keep Your Hands Clear of the Work Area SurfaceBattery and Charging System Battery and Charging SystemFirst charge new battery Hours Important Charging NotesInserting Battery Battery Indicator LightFuel Cell and Metering Valve Fuel CellMetering Valve HazardInstalling Metering Valve to Fuel Cell Prior to Use Inserting Fuel Cell Preparing the TrimMaster 18 Finish Nailer for Use FastenersLoading Fasteners Impulse and Outdoor WeatherDepth of Drive Adjustment Turn adjustment wheel in either directionRemove the battery before adjusting the depth of drive TrimMaster 18 Finish Nailer OperationFasteners and Applications ApplicationsFuel Fastener Length Applications PackRestrict Field Service to the Following Fuel Cell Check Battery CheckServicing Clearing a JamPaslode Cordless Tool Accessories Tinted Safety Glasses Part NoAir Filter End-of-Workday RoutineTroubleshooting Preparing Tool for Operation Battery/Charger ProblemsNormal Stage of Operation Troubleshooting Paslode Model Number Designation